55
FRY TOP 700/900 EL/GAS
5
TROUBLESHOOTING
5.1 INTRODUCTION
The following chapters are intended only for authorized technicians / engineers.
PROBLEM
DESCRIPTION
WHAT TO DO
CHAPTER
REFERENCE
1-
does
not
ignite / re-
main lit
Gas
pressure
supply
- there's no gas supply
- gas pressure is low
- nozzles are obstructed
Burner
-dirty/blocked aerator
-set aerator as indicated on the booklet
Pilot
Flame position / flame adjustment
§
Electrical supply
(only on models with electrical connection) there's no
electrical supply
Electronic
igni-
tion cable igniter
no spark - cable is broken or disconnected (between
electronic ignition cable and spark plug)
Spark plug
spark plug is broken or wrong positioned
Thermocouple
tension is not sufficient to open magnetic coil (gas
valve)
Safety
thermo-
stat
-reset the thermostat when at room temperature
-check thermostat intervention by measuring electri-
cal contact continuity
-oil capillary is broken
-thermostat bulb is not correctly inserted into the top
groove
-make temporary jumper to check if the PROBLEM
has resolved
Probe positioning : §
SAFETY THERMOSTAT BULB - 700 &
900
Rearm pin: §
Knob
check the knob correctly controls the gas valve
Gas valve, inlet/
outlet pressure
Outlet gas valve pressure check only on models using
gas solenoid MERTIK (900mm appliances)
Appliance requirements: §
2-
does
not
switch on
Electrical supply
electrical supply
Safety
thermo-
stat
-reset the thermostat when oil is at room temperature
-check thermostat intervention by measuring electri-
cal contact continuity
-oil capillary is broken
-thermostat bulb is not correctly inserted into the top
groove
Probe positioning : §
SAFETY THERMOSTAT BULB - 700 &
900
Rearm: §
Electrical
con-
nections
electrical connection continuity (thermostat-safety
thermostat-heating elements)
Heating
ele-
ments
compare resistance values of all heating element
electrical branches
Thermostat
contact continuity
Selector
contact continuity or loose connections
WARNING !
Take GREAT CARE when connecting / testing anything with live current, if you are unsure what you
are doing and how to use your equipment safely, then
DON'T DO IT.
Summary of Contents for A7FTEDCSI0
Page 16: ...16 FRY TOP 700 900 EL GAS GAS APPLIANCES 700 x 400mm 700 x 800mm 900 x 400mm 900 x 800mm ...
Page 39: ...39 FRY TOP 700 900 EL GAS ELECTRIC SYSTEM 700 900 ...
Page 66: ...66 FRY TOP 700 900 EL GAS 6 3 2 5 BURNER 700 900 6 3 2 6 SAFETY THERMOSTAT 700 900 ...
Page 68: ...68 FRY TOP 700 900 EL GAS 6 3 3 1 SELECTOR AND TERMOSTAT 700 900 ...
Page 70: ...70 FRY TOP 700 900 EL GAS 6 3 3 3 HEATING ELEMENT 700 900 700 900 ...
Page 71: ...71 FRY TOP 700 900 EL GAS 6 3 3 4 SAFETY THERMOSTAT 700 900 ...