FRY TOP 700/900 EL/GAS
4.2.1.3 PILOT
&
THERMOCOUPLE
INTERRUPTED
700
&
900
700 and 900 app
liances use different TC’s but the functioning is the same.
The TC, if correctly aligned with the pilot flame, will generate approx 8/10 MilliVolt, that can keep the magnetic
coil of the valve opened (coil of valve requires approx 1,5MilliVolt to keep engaged)
The TC must be inserted completley into the pilot bracket and then fixted in place by tightening the nut.