![Electrolux Professional A7FTEDCSI0 Service Manual Download Page 25](http://html.mh-extra.com/html/electrolux-professional/a7ftedcsi0/a7ftedcsi0_service-manual_2385587025.webp)
25
FRY TOP 700/900 EL/GAS
NOMINAL
GAS
PRESSURE
CHECK
The appliances are equipped with thermostatic valveS. The tech features of this valve are specially manufac-
tured for Electrolux.
Min/max tech specs tables:.
GAS / Appliance
category
Gas type
(mbar) NOMINAL
(mbar) MIN
(mbar) MAX
2nd family
2H
G20
20
17
25
2nd family
2L
G25
25
20
30
2nd family
2E
G20
20
17
25
2nd family
2N
G20/G25
20
17
30
G25
25
20
30
3rd family
3B/P
G30/G31
29
25
35
G30/G31
50
42,5
57,5
3rd family
3P
G31
37
25
45
G31
50
42,5
57,5
3rd family
3Bc
G30/G31
29
20
35