background image

Side 

1

 of 

14

 

 

 
 

ElectroHeat Sweden AB 

Phone: +46 31 764 36 30 

VAT No: SE556101713701 

Box 8065 

Fax: +46 31 54 47 02 

 

402 78 Göteborg 

Email: [email protected] 

Internet: 

www.electroheat.se

 

 

Rev:0 

 

 

 

Furnblog X5  

ElectroHeat Control System 

 

Summary of Contents for Furnblog X5

Page 1: ...14 ElectroHeat Sweden AB Phone 46 31 764 36 30 VAT No SE556101713701 Box 8065 Fax 46 31 54 47 02 402 78 Göteborg Email info electroheat se Internet www electroheat se Rev 0 Furnblog X5 ElectroHeat Control System ...

Page 2: ...47 02 402 78 Göteborg Email info electroheat se Internet www electroheat se Rev 0 Table of Contents 1 Start of Control System 3 2 Program 4 2 1 Create a heating program 4 2 2 Save Program File 7 2 3 Manage Program File 8 2 4 Start and stop 8 3 Trend 11 4 Alarm 11 5 Log file 12 6 Keyboard 13 7 Setup 13 ...

Page 3: ... starting the control system for the furnace the emergency stop circuit has to be reset manually The alarm list will start flashing and when pressing the alarm button following message will appear Confirm that the equipment is ready to start by reset the alarm list To reset the alarm list press the button Clear alarm list and reset alarms Alarm at start Alarm list Alarm starts flashing Button to c...

Page 4: ...d enter 0 minutes if program should start directly etc Unrestricted The heating will be made with full power up to typed temperature thereafter heating rate typed in Ramp Up will be used Ramp Up Desired heating rate and dwell temperature is typed in The temperature rate will be held until the dwell temperature is achieved Dwell The desired dwell time is typed in Manual Dwell When the dwell tempera...

Page 5: ...1 54 47 02 402 78 Göteborg Email info electroheat se Internet www electroheat se Rev 0 Select a segment type enter the desired values and press the right button Add segment Select Segment Type To add the second segment click on the Segment box 2 and choose a segment type for this segment Segment 2 ...

Page 6: ...roheat se Internet www electroheat se Rev 0 All programs must end with section Program Done this ends the logging of temperature for the program Program Done To delete or change a segment press on desired segment and press either of the two right buttons Delete Segment or Change Segment Delete or change segment Delete button Change button ...

Page 7: ...nother window and so on To change window press button Segment X X below segment boxes Change to segment 1 3 When all segment types have been added you have two opportunities Either you can press Save Program File to save the program or you can press Start to start the program 2 2 Save Program File When you have pressed Save Program File you will type in a name for the file and press either Save fi...

Page 8: ...he system or from an USB memory press the button Manage Program Files Here you can select List programs from system List programs from USB Copy selected program Delete selected program or open selected program Select a program and press Open selected program Manage programs 2 4 Start and stop Start and stop of heating program is managed with buttons in the upper left corner Start and stop heating ...

Page 9: ...h will show that program is running Program Running On the top you will see following parameters SP Set Point Shows continuously the desired value PV Process Value Shows continuously the actual value If PV shows NO TC it means either that there is no thermocouple wire connected or that the thermocouple is turned the wrong way Heating Output Shows power for heating in percentage used for the furnac...

Page 10: ... a graph Each segment has a color which also can be seen in the in the graph for that segment During the running of the program it s possible to change or delete a segment To do that click on the segment box you would like to change or delete Like in Picture 6 Enter the new values or delete segment When you return to the screen with the program graph press Update in the upper left corner Picture 1...

Page 11: ...se Rev 0 3 Trend In the Trend tab it is possible to see the graphs of the heat treatments Every channels temperature curves is presented in the graph Trend 4 Alarm During heat treatments Alarms can appear and the Alarm tab will start to flash By clicking on the tab a list of alarms will be shown To clear and reset the alarms press Clear alarm list and reset alarms Alarm List ...

Page 12: ... se Internet www electroheat se Rev 0 5 Log file To save a log file for a heat treatment plug in a USB memory and press the USB symbol in the lower right corner The symbol will start flash in red and green N B Don t take the USB memory out until it has stopped flashing The transfer of file can be done from any window Save log file to USB Save to ...

Page 13: ...t www electroheat se Rev 0 6 Keyboard If the keyboard other fill in windows are not visible or needs to be hidden press the keyboard in the lower right corner Keyboard 7 Setup Furnblog setup is entered by turning the maneuver breaker from 0 to 1 to make a restart of the display Therafter Enter Setup in the right upper corner is pressed Enter Setup Keyboard ...

Page 14: ...VAT No SE556101713701 Box 8065 Fax 46 31 54 47 02 402 78 Göteborg Email info electroheat se Internet www electroheat se Rev 0 OBS DON T CHANGE ANY PARAMETERS WITHOUT CONSULTING ELECTROHEAT To clear the log files press the button Clear Log Files Clear logfiles ...

Reviews: