9-249
250-255
STROBOSCOPE from slow to fast
Shutter open
8 Dimmer
0-255
Linear Dimmer 0-100 %
9 Pan/Tilt speed
0-255
Pan/tilt speed adjustment
10 Show Modes
0-59
60-159
160-255
No Function
Programs
Auto + Sound
11 Reset
0-20
21-100
101-200
201-249
250-255
No Function
PAN reset
TILT reset
PAN/TILT reset
General reset
5. Troubleshooting
A. The scanner does not work, no lights nor fan :
1.
Check the power cord and the main fuse.
2.
Check that your electrical system is working.
B. No response to DMX controller
1.
A dot must flash on the device control screen. If it’s not the case, check if cables are
properly connected and in good condition.
2.
If the dot flashes, check your addressing as well as the polarity of your DMX wiring.
3.
Try an other DMX controller
4.
Avoid to lay your DMX cables alongside high-voltage lines to avoid interference.
C. In Master/Slave Mode some devices don’t properly respond
1.
Check cables and the connection diagram.
2.
Check that devices are properly assigned in Master/Slave mode.
6. Cleaning
Before any cleaning operation, unplug the scanner power cord in order to avoid any
electrocution risk. Cleaning the optic must be done periodically in order to optimize the
scanner’s brightness. The cleaning frequency depends on the operating environment. Smoke
and dust may cause a large accumulation of dirt upon the scanner’s optics :
-
Clean it with a soft dry cloth.
-
Do not use liquid or detergent products.
-
Clean external lenses approximately every 20 days, with a soft dry cloth, without overly
pressing on the lenses.
8
Summary of Contents for SCANNER 30
Page 9: ...La gare 69620 CHAMELET 9 ...