ELECTROCOMPANIET ECI2 Owner'S Manual Download Page 7

Technical Specifications ECI 2 :

The following technical data were measured on randomised test objects and are typical
data. All measurements are made with the following equipment:
Distortion analyser:

Tektronix AA501

Oscilloscope:

Tektronix 468

Oscillator:

Tektronix SG505

Frequency counter:

Rascal 9838

Phase meter:

Hewlett Packard 3575A

Preamplifier section

 

Input impedance

17 kOhm

Max. input

> 14 Volt RMS

Equivalent input noise

< 3 µV

Input sensitivity for rated output

0.3 V

 

 

Amplifier section

 

Main voltage 120 V / 240 V. Clipping point of the amplifier is set to a level where total
harmonic distortion (THD) is 0.2 %.

Output Impedance (20 Hz - 20 kHz)

< 0,01 Ohm

Max. peak current

> 45 A

THD (measured at 1 kHz half power, 8 Ohm)

< 0,005 %

THD (measured at 1 kHz -1 dB 8 Ohm)

< 0,005 %

 

 

Rated output power  

10 % change in line voltage will give app. 20 % change in output power.

8 Ohm 2 x 50 W
4 Ohm 2 x 90 W
2 Ohm 2 x 150 W
 

 

Power consumption (no load or signal)

70 W

 

 

Dimensions  
Width

432 mm / 17 inches

Depth

400 mm / 15.8 inches (incl. handles)

Height

115 mm / 4.5 inches

Weight

11Kg / 24.2 lbs.

The manufacturer reserves the right to alter these specifications without further notice.

Summary of Contents for ECI2

Page 1: ...t expose this appliance to rain or moisture Verify line voltage before use Do not remove cover No user serviceable parts inside Refer servicing to qualified service personnel The warranty in void if t...

Page 2: ...s immediately recognised as dramatically more musical sounding than any other transistor amplifier The same design philosophy has been constantly updated by additional research and development This ph...

Page 3: ...ied around individual stages of the amplifier circuit This approach allowed us to avoid the sonic disadvantages of overall feedback from output to input The concept was further developed to reduce pha...

Page 4: ...line voltage in the territory were you intend to use your amplifier How to avoid damages A good operating practice is to turn off all equipment before any connections or disconnection s are made Do no...

Page 5: ...n the unit off and remove the AC cord from the inlet Open the drawer with a small screwdriver and remove the broken fuse The spare fuse is located in the hole in front of the main fuse Push the new fu...

Page 6: ...charges insurance re importation to your country and duty arrangements When shipping a product to the factory for service always include the following 1 A sales slip or other proof of purchase if rep...

Page 7: ...3 V Amplifier section Main voltage 120 V 240 V Clipping point of the amplifier is set to a level where total harmonic distortion THD is 0 2 Output Impedance 20 Hz 20 kHz 0 01 Ohm Max peak current 45...

Reviews: