background image

How to connect your system

See illustration 1 and illustration 3

Inputs

Single- ended operation:
All inputs are similar regarding sonic performance.
Unused inputs may be shorted to ground, using a RCA shorting plug.

Balanced operation:
There are three set of balanced inputs.
Two set for 6 channel operations, labelled Input 1 and Input 2, and one set for 2 channel
operations labelled CD.
Note that the two 6 channel inputs may also be used for 2 channel operations.

Outputs

REC:
Rec outputs are used for recording.
The source you listen to will be monitored through this output.
The record function is not influenced by the volume control setting.

Never use shorting plugs in outputs.

LINE OUT:
The line out is a variable output, dependent on the volume control setting and MUTE function.
These outputs controls the power amplifier(s).

SPAC:
These contacts are used to communicate with power amplifiers AW 2x120 and AW 3x120.
Connect a SPAC Com cable (sold separately) from SPAC A to one of the amplifier and SPAC B to 
the other. When these cables are connected to the amplifiers the amplifiers will automatically switch 
to mono mode when running 2 channel sources.
SPAC Multi is reserved for future use. 

DATA:
Connect an USB cable from the DATA port to a PC to upgrade the software on the EC 4.9.

REMOTE CHARGE:
Connect the remote ECT2 (sold separately) to this port to charge the remote.

Summary of Contents for EC 4.9

Page 1: ...EC 4 9 ...

Page 2: ...r any circumstances connect or disconnect equipment when power is turned on The design of the RCA plug generates a huge transient when inserted Connecting or disconnecting equipment with the power on can result in severe damage to both speakers and amplifier How to avoid noise problems The EC 4 9 contains delicate circuits that are sensitive to magnetic stray fields The unit should not be placed n...

Page 3: ...function is not influenced by the volume control setting Never use shorting plugs in outputs LINE OUT The line out is a variable output dependent on the volume control setting and MUTE function These outputs controls the power amplifier s SPAC These contacts are used to communicate with power amplifiers AW 2x120 and AW 3x120 Connect a SPAC Com cable sold separately from SPAC A to one of the amplif...

Page 4: ...D 2 channel balanced operation on source connected to CD input Tuner 2 channel single ended operation on source connected to Tuner input Tape 2 channel single ended operation on source connected to Tape input DVD 2 channel single ended operation on source connected to DVD input In daily operation switch off the EC 4 9 by turning the volume control down When the EC 4 9 is not to be used for a long ...

Page 5: ...a All measurements are made at 120V 240V 50Hz 60Hz Measurements Single ended Balanced Input impedance 47 kOhm 47 kOhm Output impedance 100 Ohm 100 Ohm Maximum gain 6 dB 6 dB Minimum gain 111 dB 111 dB Noise floor 0 dB gain 130 dB 130 dB THD 1V in 1V out 120 dB 130 dB Max input 15Vp p 30Vp p Max output 30Vp p 30Vp p Frequency response 1 200 kHz 1 200 kHz Channel separation 120 dB 120 dB Power consu...

Page 6: ...to the following address ELECTROCOMPANIET AS BREIVIKVEIEN 7 4120 TAU NORWAY Switchboard 47 51 74 10 33 Fax 47 51 74 10 10 Service 47 51 74 10 23 E mail sales electrocompaniet no Web www electrocompaniet no Service department service electrocompaniet no The end user is responsible for all shipping charges insurance and re importation and duty charges When shipping a product to the factory for servi...

Page 7: ...Illustration 1 Back panel Illustration 2 Front panel ...

Page 8: ... Right Sub Surround Left Surround Right Centre In 2 2 Channel In 2 Front Left Front Right Front Left Front Right Multichannel amplifiers will be bridged to mono mode if connected to Spac A or B CD CD Balanced Front Left Front Right Multichannel amplifiers will be bridged to mono mode if connected to Spac A or B Tuner Tuner Single ended Front Left Front Right Multichannel amplifiers will be bridged...