B.  Battery Type Selection

GEL

: Sealed type (VRLA) , GEL , Maintenance Free , Automotive or Deep Cycle lead acid batteries

WET

: Flooded Type lead acid batteries (to which water can be added) Automotive or Deep Cycle 

Calcium-Calcium : Calcium-Calcium type batteries are to be charged in this mode only when boost is required (15.5V). No load 

is to be connected to the battery during this charge mode. Charge through one cycle only then set back to 
WET charge setting.

B1. FLOAT VOLTAGE SELECTION

These fine tuned selections of float voltages enable the best voltage level for maximum battery life. Choose 13.8V when in doubt
or in Power Supply Mode.
Follow the markings on Deep Cycle batteries of the Standby float voltage.

B2.   Recommended  Battery Capacity 

The following minimum AH capacities are  a generalized suggestion, some batteries can take higher charge current, check with
battery manufacturers for charging batteries with smaller capacity. 

Charger Model

BC-1210 ,10A

BC-1215 ,15A

BC-1220 ,20A 

Battery Capacity

40 AH - 100 AH 

60 AH - 150 AH

80 AH - 200 AH 

C. Battery Charger Installation and Connection

Observe the warnings & safety precautions before connecting the charger.
Check battery condition, fill up cells for wet battery, clean battery posts.
Secure the battery charger in a well ventilated place, make sure the mounting surface is flat. The air intake is at the bottom and air
outlet at the back. Make sure both intake and outlet are not blocked. Never place charger on top of battery.
Plug in the AC mains and turn on Power Switch , the Charger On LED and the Float LED should be on green indicating Charger is
in good order for charging.
Before connecting or disconnecting the charging cable, turn off the Power Switch and unplug AC cord  from the mains.
First connect the Red cable to Po terminal of charger and the battery Po Post. Then connect the Black cable to the
Negative – terminal and the Negative – Post of the battery.
Make sure all the connections are tight and secure.
Double check again for correct selection of Slide Switch 1 at Charger Mode, Switch 2 for Battery type and  Switch 3 for Float
Voltage setting value.

D. Normal 3 Stage (IUoU) Charging Operation 

The 3 stage IU0U charge algorithm ensures fast , complete and at the same time gentle charging of the lead acid battery.

Fig.2

Summary of Contents for BC-1210

Page 1: ...attery Wear protective goggles and turn your face away when connecting or disconnecting the battery Never place the charger on top of a battery Never smoke use an open flame or create sparks near battery or charger during normal charging operation as batteries may give out explosive gas Do not charge batteries in an enclosure box in due to possible explosion of entrapped explosive gas Disconnect t...

Page 2: ...election Slide Switch to set Charger to 3 Stage Charger or Power Supply Mode See Section G 3 Battery Type Selection Slide Switch to set charger for GEL Wet and Calcium Calcium type battery 4 Float Voltage Selection Slide Switch to set Float Charge voltage to 13 2 13 5V 13 8V 5 Charge Status LED Display Charger ON LED Green 3 Stage Charger Mode Red Power Supply Mode BULK LED Red Bulk Charging with ...

Page 3: ...tery Charger Installation and Connection Observe the warnings safety precautions before connecting the charger Check battery condition fill up cells for wet battery clean battery posts Secure the battery charger in a well ventilated place make sure the mounting surface is flat The air intake is at the bottom and air outlet at the back Make sure both intake and outlet are not blocked Never place ch...

Page 4: ...of same chemical make up and type to avoid over and under charging because only one setting of charging profile for both Two batteries are charged simultaneously and the battery with the lowest level gets most share of the current in the Bulk charge stage until it is up to the same voltage level of the second battery battery with higher initial level Both batteries will go to the Absorption and th...

Page 5: ... is used to optimise charging over wide ambient temperature range Fix the temperature sensor optional accessory in a position on the battery which is not affected by other cooling or heating source Plug in the temperature sensor then switch on the charger to activate the temperature control function never plug in the sensor during charging Fig 4 ...

Page 6: ...light does not come on even after 20 hours charging time Absorption light remains on all the time Wrong battery type Total battery capacity is too high for dual charging Battery temperature too high Battery is defective A load is connected to battery and charger is not in power supply mode Check charged battery label and change battery type selection to correct setting Check battery capacity or ch...

Page 7: ... Current or 50 Rated Output Current Soft Charge Protection Type Constant Current Limiting recovers Automatically after Fault Condition is Removed Short Circuit Recovers Automatically After Fault Condition is Removed Reverse Polarity Car Blade Fuse Over Temperature Protection Type Automatically de rate Charge Current Until Zero or Shut Down OVP Output Over Voltage Yes Cooling Cooling Method Convect...