System Applications:
8 XLD-Biamp (3 Segments) – Very-Compact for Medium Venues
Cabinets:
16 x XLD 281, 4 x XS212
Horizontal Coverage
2 x 120 deg
Amplifiers:
8 x CP 3000S
Typical: Distance
120dB SPL @ 40 m (130ft)
Controllers:
4 x DX38
Total Amp: Power
2 x 7.600 W = 15.200 W
Cabling:
6 x NL8 long, 14 x NL8 short
Accessories:
4 x XLD Grid, 2 x Coupler-Beam, 3 x XLD Dolly
3 contol segments for optimized array control. Optional drive: 6 x P1200RL & 2 x P3000RL, or 6 x CP2200 & 2 x CP3000RL.
For bass extension add 2 XA212 per side.