background image

Installation and Suspension of TL880P

Enclosures

The  TL880P is designed for typical cinema

stage (behind-the-screen) applications where

subwoofers are mounted on the stage floor.

In addition to the following specific infor-

mation, the user may refer to the P1250

owner’s manual.

The TL880P is not designed to he self-sus-

pended from above, and if suspended,

must be supported and hung in a way

which does not depend on the structure

of the TL880P itself for support.

Overall System Installation

Precautions

Please read the entire engineering data sheet

before connecting the TL880P to your sys-

tem. For optimum performance, observe the

following precautions:

1.

2.

3.

4.

5.

Keep the ac power switch off while

making connections.

Be certain that connectors are tightly

mated. Loose connections cause hum,

noise or intermittences  that could dam-

age your speakers.

Use the proper, high-quality shielded

cables in your entire system. Low-ca-

pacitance cable is preferred.

Turn on the electronic equipment which

feeds the TL880P  first. Wait eight to

ten seconds, then turn on the P1250

amplifier. This prevents any transient

“pop” which could damage a loud-

speaker

To prevent fire or electrical shock, do

not expose the TL880P to rain or ex-

cess moisture.

Driving Multiple TL880P’s

The

 high, 20,000-ohm  input impedance of

the  P1250 power amplifier allows several

TL880P systems to be connected in parallel

(daisy chained) to the usual single signal

source, without undesirable loading effects

on the source. Extra connectors on the PI 250

facilitate such daisy chaining.

Signal Input and Polarity Convention

The P1 250 channel A input connector should

be used. It is easily accessible through the

access/vent opening in the speaker enclosure

side closest to the top of the amplifier. The

connector is a three-pin female connector, pin

2 hot. The TL880P does not invert polarity,

i.e., a positive voltage on pin 2 of the Pl250’s

input connector produces a positive (out-

ward) movement of the loudspeaker cones.

This relationship is important under some in-

stallation conditions.

P1250 Input Attenuator Settings

In the factory bridged mono mode, only the

channel A input attenuator is operative.

During system set up, the attenuator should

be set in the full-counterclockwise “off’ po-

sition, in order to avoid inadvertent and pos-

sibly excessive output from the TL880P.

When the TL88OP  is first operated under sig-

nal conditions, the attenuator should be ad-

vanced only slightly to check for signal in-

tegrity (the P1250’s front-panel channel A

green input LED helps in this regard). Once

proper system operation is confirmed, the

control may be advanced to a point that pro-

vides, in conjunction with the chosen drive

level from upstream equipment, the desired

acoustic output level in the room. 

System Physical Orientation and Placement

Any orientation of the TL880P is acceptable,

as long as the air flow through the power

amplifier is not impeded. A minimum clear-

ance of 76 mm (3 in.) should be maintained.

Architects’ and Engineers’ Specifications

The loudspeaker system shall be an ampli-

tied, dual-low-frequency, bass-reflex design.

Two 18-inch woofers shall be front mounted

in a 414-liter  (14.6-cuft) enclosure. The sys-

tem shall meet the following criteria: The

loudspeaker shall be capable of handling a

total of 1,200 watts long-term average with

a 6-dB crest factor per ANSI/EIA  RS-426-A

1980. The system shall reproduce frequen-

cies to below 23 Hz at a usable level when

used in “step-down” mode with the supplied

port cover in place. The combined sensitiv-

ity of the loudspeakers shall be 98 dB at one

watt, one meter (100 to 800 Hz). The enclo-

sure shall be constructed of black texture

painted plywood containing sound-absorb-

ing glass wool. The amplifier shall be side

mounted and contain the necessary circuitry

to provide all the equalization and protec-

tion needed to operate the system in step

down mode. The system, with minor modifi-

cation, can be used as a conventional vented

box and amplifier. The enclosure dimensions

shall be  1.21m  x  0.76m  x  0.60m  (47.5 in. x 

30 in. x 23.8 in.) (hwd) Net weight shall be

89.6 kg (197.5 lb)

The very-low-frequency system shall be the

Electro-Voice  TL880P

Uniform Limited Warranty

Electro-Voice products are guaranteed

against malfunction due to defects in mate-

rials or workmanship for a specified period,

as noted in the individual product-line

statement(s) below, or in the individual prod-

uct data sheet or owner’s manual, beginning

with the date of original purchase. If such

malfunction occurs during the specified pe-

riod, the product will be repaired or replaced

(at our option) without charge. The product

will be returned to the customer prepaid.

Exclusions and Limitations: 

The Limited

Warranty does not apply to: (a) exterior fin-

ish or appearance; (b) certain specific items

described in the individual product-line

statement(s) below, or in the individual prod-

uct data sheet or owner’s manual; (c) mal-

function resulting from use or operation of

the product other than as specified in the

product data sheet or owner’s manual; (d)

malfunction resulting from misuse or abuse

of the product; or(e) malfunction occurring

at any time after repairs have been made to

the product by anyone other than Electro-

Voice Service or any of its authorized ser-

vice representatives. 

Obtaining Warranty

Service: 

To obtain warranty service, a cus-

tomer must deliver the product, prepaid. to

Electro-Voice Service or any of its autho-

rized service representatives together with

proof of purchase of the product in the form

of a bill of sale or receipted invoice. A list

of authorized service representatives is avail-

able from Electro-Voice Service at 600

Cecil Street, Buchanan, MI 49107 (800-234-

6831 or 616-695-6831). 

Incidental

and Consequential Damages Excluded:

Product repair or replacement and return to

the customer are the only remedies provided

to the customer. Electro-Voice shall not be

liable for any incidental or consequential

damages including, without limitation, in-

jury to persons or property or loss of use.

Summary of Contents for TL880P

Page 1: ...en the screen and theatre wall often makes it difficult to con nect to the back of an enclosure Directivity In addition to motion picture applications the TL880P is highly appropriate as the subwoofer in large multiway systems for contemporary music playback and sound reinforcement The TL88OP has more output below 40 Hz than the devices typically used in these applications in either the normal 25 ...

Page 2: ... Subpassband Speaker Protection The P1250 power amplifier provides 12 dB per octave infrasonic protection of the EVX 18OA s below the P125O s peak boost frequency of 26 Hz Protection is increased to 24 dB per octave below 15 Hz P1250 Settings The TL880P is shipped with the P1250 rear panel processor settings set for step down mode See Figure 6 The speakers are con nected to the central bridged out...

Page 3: ...s not impeded A minimum clear ance of 76 mm 3 in should be maintained Architects and Engineers Specifications The loudspeaker system shall be an ampli tied dual low frequency bass reflex design Two 18 inch woofers shall be front mounted in a 414 liter 14 6 cuft enclosure The sys tem shall meet the following criteria The loudspeaker shall be capable of handling a total of 1 200 watts long term aver...

Page 4: ... are guaran teed against malfunction due to defects in materials or workmanship for a period of three 3 years from the date of origi nal purchase Additional details are in cluded in the Uniform Limited Warranty statement Electro Voice Accessories are guar anteed against malfunction due to de fects in materials or workmanship for a period of one 1 year from the date of original purchase Additional ...

Page 5: ...P Amp Settings for Step Down Operation as shipped 300 300 200 100 80 60 40 30 20 20 30 50 100 200 500 1000 2000 FREQUENCY Hz FREQUENCY k P1250 Amplifier Settings 5 3 Hz LIMITER TIME coNsTAM Jp4 pHZ Ems D gay 5r PRCCE POLE iILlER FREQMNCY IF2 FAST SLiM BRIDGED NORMAL The settings above require the vent cover to be in place as delivered for proper and safe operation of the system ...

Page 6: ...ter Frequency 15 Hz as shipped Slope 12 dB as shipped Enclosure Materials and Colors Black texture painted poplar plywood Amplifier Safety Approvals in procedure UL 8 13 CSA C22 2 IEC 65 ENG 0065 EMC Directive for European RFI EMI emissions Dimensions Height 1 21 m 47 5 in Width 762 mm 30 0 in Depth 605 mm 23 8 in Net Weight 89 6 kg 197 5 lb Shipping Weight 97 6 kg 215 3 lb Amplifier see P1250 doc...

Reviews: