EVID Surface Mount S Series - X Models
Installation and wiring | en
13
Electro-Voice
Installation Manual
2022-03 | 07 | F.01U.345.358
6.
Adjust the
tap settings
, if needed.
7.
Mount the
speaker
, as shown in the installation section.
8.
Plug the
Euroblock connector
into the speaker.
9.
Insert the
four
screws
into the weather cover (B).
Loosely tighten the four screws to keep the weather cover in place.
10. Tighten all
four
screws
to secure the weather cover.
Ensure the weather cover is secure.
11. Adjust the
wire
length.
12. Tighten the remaining gland nut (C).
Refer to
–
Installing the speaker, page 8
3.5
Transformer taps
You can select the mode of operation (70 V/100 V/8 ohm) and power taps using the rotary
switch on the input panel.
i
Notice!
For UL1480/ULC-S541 fire installations, the speaker is not intended for connection to DC
supervised systems.
Please refer to the compatible fire alarm control unit manual for additional wiring and
supervision instructions.
i
Notice!
For EN54-24 fire installations, the speaker is not intended for connection to DC supervised
systems.
Configuring the transformer settings
To
configure the transformer settings
, do the following:
1.
Select the desired
power tap
by using the rotary switch on the input panel.
+
A
2.
If 8 ohm mode is desired, remove the
safety screw
.
Safety screw (A) is shown in the previous step.
3.6
Replacing the logo
An additional logo is included, horizontal installation is shown.