Models  EST12, EST24 and EST32

Installation and Maintenance Instructions

THE FOLLOWING ARE CAUTIONARY STATEMENTS THAT MUST BE READ AND FOLLOWED

DURING BOTH INSTALLATION AND OPERATION

WARNING:

Raritan Engineering Company, Inc. recommends that a qualified person or electrician install this
product. Equipment damage, injury to personnel or death could result from improper installation.
Raritan Engineering Company, Inc. accepts no responsibility or liability for damage to equipment,
or injury or death to personnel that may result from improper installation or operation of this
product.

WARNING: HAZARD OF SHOCK AND FIRE

 - Always use recommended fuse/circuit breaker and wire size.

WARNING: HAZARD OF FLOODING

 - Always shut off seacocks before leaving boat unattended.

Double clamp all hose fittings below the waterline, check hose clamps frequently for integrity.

WARNING:

The electro scan operates on an Electrochemical principle.  Introduction of any substance other than
salt water, human waste, Raritan Concentrate, Raritan C.P. or toilet tissue may cause heat build up
and extensive damage.  If any other substance is introduced by accident, the electro scan must not
be turned on until entire system is flushed out with water.

electro scan™ is a U. S. Coast Guard Certified Type I Marine Sanitation Device for use on inspected and
uninspected vessels 65 feet (19.7 Meters) and under. It must be operated within areas that are not declared
a Federal No Discharge Zone (NDZ) by the U.S. Environmental Protection Agency (EPA).  This is applicable
for all U.S. territorial waters inside the three mile limit. Other countries - check with local authorities.

electro scan is designed for recreational use and accommodates most marine toilets* it can be used with one
or, in some cases, two toilets.  The electro scan is available in 12, 24 or 32 V DC.

The system consists of a Control Unit, LCD Display, System Status Panel and Treatment Tank.

A salt feed system (optional) 

must

 be utilized if operating in fresh or brackish water. Please

see Page 7 for complete details on Salt Feed Options.

electro scan with control

 optional salt feed systems

2 gallon tank

4 gallon tank

for use with the VacuFlush

®

 marine toilet manufactured by Sealand Technology, Inc., (See Application note L286)

VacuFlush

®

 is a registered trademark of Sealand Technology, Inc.

 electroscan

™ 

is a trademark of Raritan Engineering Co., Inc., patent pending

TM

Summary of Contents for EST12

Page 1: ...ther substance is introduced by accident the electro scan must not be turned on until entire system is flushed out with water electro scan is a U S Coast Guard Certified Type I Marine Sanitation Devic...

Page 2: ...w it works Each time the toilet is flushed an equal amount of previ ously treated waste is discharged The electro scan does not pump waste out The flushing action of the toilet moves the waste through...

Page 3: ...to time screen using and keys when unit is not in cycle Hold mode button until digits flash use and button to set hour in military time Push mode again for next digits minutes Use and to set minutes R...

Page 4: ...goes to treatment cycle after pretreatment for 120 seconds voltage and amps are displayed alternately During the treatment cycle if electrode amps drop below 14 Warning is displayed and cycle is exten...

Page 5: ...to any components 3 Turn Power off 4 Disconnect Red White and orange wires at Electroscan control box WARNING electro scan must not be activated without disconnecting electrode and motor wires while m...

Page 6: ...s and turn power on NOTE electro scan treatment tank must be full with sea water salinity water before activating a cycle 3 Flush toilet using one of the following methods to fill the treatment tank w...

Page 7: ...only be used with the electro scan One system per electro scan This is the most accurate system to use as the amount of saturated salt solution is controlled by the actual operating conditions of the...

Page 8: ...les Y valves if installed must direct toilet discharge to a U S C G approved treatment system or holding tank and must be secured in that position while inside the three mile limit The EPA standards s...

Page 9: ...be replaced with the same type to maintain ignition protection Treatment Unit 1 Determine proper wire size from wire chart on specifications page 2 Run supply wire from source Positive POS to control...

Page 10: ...p button is pressed both toilet and electro scan will activate Toilet flush time is controlled by Control box and can be adjusted factory preset is for 10 seconds Option 2 Toilet Push Button Flushing...

Page 11: ...6 7 21 1 RARITAN AUX HEAD 2 HEAD 1 SALT FD NEG NEG NEG NEG MAN IN MAN IN EXT TRIG EXT TRIG FUSES HD NEG HD POS To TO LST on second Atlantes toilet To FROM LST on second Atlantes toilet Wiring Atlantes...

Page 12: ...p m a e d o r t c e l e g n i s u a c t l a s w o L 1 s p m a e m o s s e r i u q e r r e t a w h s e r f h t i w n o i t a l l a t s n i w e N 1 m e t s y s d e e f t l a s t r a t s o t k n a t t n...

Page 13: ...a W r o y a l p s i D t l a S w o L 1 k c a P e d o r t c e l E y t r i D 2 f o t h g i e w y b z o 2 1 8 h t i w r e t a w f o s n o l l a g 2 d d A 1 d e e f t l a s k c e h C e l c y c a n u r d n...

Page 14: ...31 113 2 31 115 31 121 31 122 32 5000 33 5000 or 34 5000 31 112 31 109 31 103 31 106 31 110 2 31 110 1 31 106 31 107 31 101W 31 122 31 114 31 108 31 103 32 700 33 700 or 34 700 31 702 31 705 32 102A 3...

Page 15: ...ck 31 3001 Salt tank unit complete two gallon not shown 31 3002 Four gallon salt feed tank not shown 32 3003 Four gallon salt feed tank w 12 volt pump not shown 33 3003 Four gallon salt feed tankw 24...

Page 16: ...REMEDY FOR BREACH OF CONTRACT WHICH BUT FOR THIS PROVISION MIGHT ARISE BY IMPLICATION OR OPERATION OF LAW IS HEREBY EXCLUDED AND DISCLAIMED ALL IMPLIED WARRANTIES SUCH AS THOSE OF MERCHANTABILITY AND...

Reviews: