5. Troubleshooting
If the FiberCom Media Converter fails to operate, follow these steps:
No:
-
Is the power supply compatible with the AC
outlet?
-
Is the power supply installed properly in the
FiberCom and the AC outlet?
-
Contact EIG’s technical support.
1. Is the FiberCom’s “PWR” LED
illuminated? (See page 10)
Yes: continue to step 2.
2. Is the “FDX/COL”LED
illuminated on a port with
twisted-pair cable installed?
No:
-
The FiberCom has selected half-duplex
mode.
Yes:
-
The FiberCom has selected full-duplex
mode.
If the mode is not correct, disconnect and reconnect the
twisted pair cable to restart the initialization process.
Continue to step 3.
No:
-
Check the fiber cables for proper
connection.
-
Verify that the TX and RX cables are
connected to the FiberCom’s RX and TX
ports, respectively.
3. Is the “Link/Act” LED
illuminated on the on the fiber
cable port?
Yes: continue to step 4.
4. Is the “100M” LED
illuminated on a port with
twisted-pair cable installed?
No:
-
The FiberCom has selected 10Mbps
operation.
Yes:
-
The FiberCom has selected 100Mbps
operation.
If the speed is not correct, disconnect and reconnect the
twisted pair cable to restart the initialization process.