![ELECTRO FREEZE SOFT SERVE TWIST SL500 Operator'S Manual Download Page 47](http://html.mh-extra.com/html/electro-freeze/soft-serve-twist-sl500/soft-serve-twist-sl500_operators-manual_2379682047.webp)
ELECTRO FREEZE Soft Serve Model SL500
38
184599
12
Trouble Shooting Tables
(continued)
PROBLEM
PROBABLE
CAUSE
REMEDY
1.
Dirty condenser.
1. Have condenser cleaned by your
Electro Freeze distributor.
2.
Shortage of refrigerant.
2. Contact your Electro Freeze Distributor
for service.
3.
Moisture in system.
3. Contact your Electro Freeze Distributor
for service.
Unit operates
long or
continuously.
4.
Compressor failing.
4. Contact your Electro Freeze Distributor
for service.
Discharge
pressure too
high.
1.
Water supply hose kinked or pinched.
(water cooled models)
1.
Move f reezer and adjust hose so it is not
pinched or kinked.
2.
Water t urned off or defective water
regulating valve. (water cooled models)
2.
Turn on water, or contact your Electro
Freeze Distributor for service.
3. Restricted
water
cooled
condenser.
(water cooled models)
3.
Contact your Electro Freeze Dist ribut or
for service.
4.
Dirty air condenser. (air cooled models)
4.
Contact your Electro Freeze Dist ribut or
for service.
5.
Unit location too warm (air cooled
models)
5.
Contact your Electro Freeze Dist ribut or
for service.
6.
Ref rigerant overcharge.
6.
Contact your Electro Freeze Dist ribut or
for service.
7.
Air or non-condensable in refrigeration
system.
7.
Contact your Electro Freeze Dist ribut or
for service.
1.
Tubing rattles.
1.
Contact your Electro Freeze Distributor
for service.
Noisy
compressor.
2.
Spring broken internally.
2.
Contact your Electro Freeze Distributor
for service.