background image

socket.  Remove  the  lamp  from  the  support 
clip. Remove the plastic lamp support clips by 
pinching  the  back  of  the  clip  and  lightly 
pulling away from the reflector. 

4.  Before  replacing  the  lamps,  the  reflector 

should  be  cleaned  with  a  soft  cloth  and  mild 
non-abrasive soap.  

5.  Replace  the  support  clips  by  pressing  them 

into the hole in the reflector. 

6. 

NEVER

  use  any  lamp  other  than  from  the 

original  manufacturer. 

NEVER

  run  the  Air 

Cleaner with only one lamp. 

7.  When  replacing  the  lamp,  use  gloves  to 

prevent oil from being deposited on the glass. 
Hold the lamp by the base and slide the glass 
end  into  the  plastic  support  clip.  Slide  the 
lamp  straight  into  the  lamp  socket  until  the 
lamp locks into place. 

8.  Remove the new PCO filter from the bag and 

slide into the upper track under the lamps with 
the  fuzzy  side  towards  the  lamps.  During 
shipping and handling a small amount of white 
dust  is  created.  This  can  be  cleaned  by 
vacuuming. 

DO NOT

 vacuum the filter. 

9.  Remove the final filter from the bag and slide 

it  into  the  track  below  the  PCO  filter  with  the 
arrow pointing away from the PCO filter. 

10. Replace  the  lamp  access  panel  tightening  all 

screws. Do not over tighten. 

Note:

 When the filters are new, you may notice a 

new  smell  from  the  system.  This  is  normal  and 
will dissipate within a few hours. 
The  PCO  Filter  will  discolor  with  use.  This  is 
normal. 

PCO  Filter  (#DM900-0450):

  This  must  be 

replaced every 2 years.  

Final  Filter  (#DM900-0810):

 Must be replaced at 

least once a year.  

UVC  Lamp  (#DM900-0191)  (2  required):

 

Replace  every  2  years.  Includes  lamp  support 
clip. Lamp may still light after 2 years but intensity 
of the germicidal wavelength will be reduced. 

UVC  Lamp  /  PCO  Maintenance  Kit  (#DM900-
1002): 

Contains  2  UVC  lamps,  2  lamp  support 

clips, 1 PCO filter and gloves. 

Complete  2  Year  Maintenance  Kit  (#DM900-
1003): 

Contains 1 HEPA filter, 4 carbon prefilters, 

2  UVC  lamps,  1  PCO  filter,  2  carbon/potassium 
permanganate final filters, gloves. 

Dimensions 

 

Height 

 

 

 

Width 

 

 

 

Depth 

29.5 in 

16.25 in 
12.75 in 

74.9 cm 
41.3 cm 
32.4 cm 

Intake 

14.5 x 3.75 in or 8 in (dia) 

36.8 x 9.5 cm or 20.3 cm (dia) 

Outflow 

14.5 x 4.37 in or 8 in (dia) 

36.8 x 11.1 cm or 20.3 cm (dia) 

Unit Weight 

47 lbs 

21.3 kg 

Input Voltage 

120 V    60 Hz 

 

Power Consumption 

200 Watts 

 

Air Flow:                       EADM900UV-VO-A 
       EADM900UV-VO-VS (Variable Speed) 

250 CFM 

up to 250 CFM 

424.8 m³/hr 

up to 424.8 m³/hr 

Cabinet 

22 gauge 

 

Power Cord 

9.0 ft 

2.74 m 

Filter Dimensions                     Prefilter 
 

 

 

     HEPA Filter 

 

 

 

     PCO Filter 

                                                Final Filter 

16 x 12 x 1 in 

16 x 12 x 2.5 in 

16 x 10 x 0.375 in 

16 x 10 x .5 in 

40.6 x 30.5 x 2.5 cm 

40.6 x 30.5 x 5 cm 

40.6 x 25.4 x 0.95 cm 

40.6 x 25.4 x 1.3 cm 

Ultraviolet Power in Reflector 

>10,000 μW/cm² 

 

HEPA Collecting Surface Area 

40 ft² 

3.7 m² 

TECHNICAL DATA 

CAUTION  

The  lamps  contain  a  very  small  amount  of  mercury 
(Hg).  In  case  of  accidental  breakage,  handle  with 
extreme  care.  According  to  the  EPA  website,  open 
windows in the affected area and leave the room for 15 
minutes.  Do  not  vacuum  or  use  a  broom  to  clean. 
Wear  a  dust  mask  and  use  disposable  gloves.  Scoop 
fragments  using  stiff  paper  or  cardboard.  Place 
fragments in a plastic bag. Wipe area with damp paper 
towels  and  place  towels  in  the  plastic  bag.  Seal  bag 
and dispose of waste following local guidelines. Wash 
hands  with  mild  detergent  and  water.  See  the  EPA 
website (www.epa.gov) for more information. 

CAUTION  

Always  dispose  of  plastic  bags  safely.  Do  not  allow 
children or pets to play with empty plastic bags. 

CAUTION  

The lamps used in this air cleaner contain a very small 
amount  of  mercury  (Hg).  The  lamps  should  be 
disposed  of  according  to  local  ordnances  or  refer  to 
www.lamprecycle.org. 

Summary of Contents for EADM900UV-VO-A

Page 1: ...Photo Catalytic Oxidation Filter removes unpleasant odors and Volatile Organic Compounds Carbon Potassium Permanganate Final Filter removes non organic gases Kills or inhibits bacteria viruses mold fungi and microbial growth Easy to change Filters and Lamps Powerful motor delivers 250 CFM FSDM900UV VO A or up to 250 CFM FSDM900UV VO VS Variable Speed of clean sterilized air Heavy gauge galvanized ...

Page 2: ...time and redecorating costs Provides a healthier more comfortable environment year round HOW IT WORKS Millions of airborne pollutants are carried through the return air ducts of the heating cooling system The Air Cleaner has been designed to be installed on the return air duct A portion of this return air is by passed through an opening on the rear or top of the unit and passes through a 5 stage f...

Page 3: ... the holes on the top or bottom of the unit if you are duct mounting the Air Cleaner Bend all the flaps outward slightly less than 90 degrees except for the upper bottom flap which is only bent up 45 degrees This bottom flap will act as a deflector for the exhaust air entering back into the plenum 5 Place the gasket material around the two openings on the back of the air cleaner 6 Place the unit o...

Page 4: ...r direct it should be added to the system before the intake inlet to the Air Cleaner 5 The 8 inch intake collar top must draw air from the return duct at a location that will be ahead of the clean exhaust air that will be returned to the duct from the Air Cleaner An 8 inch collar will be installed on the return duct and a length of 8 inch flexible hose or duct is required to attach between the 8 i...

Page 5: ... cord to be placed where it may be walked on or allow anything to roll over it MAINTENANCE For efficient operation the filters must be changed on a regular basis If you notice a reduction in air flow from the system check the filters WARNING Never use the Air Cleaner without all of the filters in place and all cover panels and doors closed Make sure all the screws are in place CAUTION Make sure to...

Page 6: ...tancy of the HEPA filter Note Handle the HEPA filter by the frame only The paper is fragile and a puncture or tear will reduce efficiency Replacing the UV Lamps PCO Filter and Final Filter 1 To change the PCO filter Final filter and UV lamps turn the Air Cleaner OFF and UNPLUG it Remove the screws from the lamp access panel and remove the panel DO NOT misplace the parts 2 Carefully remove the filt...

Page 7: ... 1002 Contains 2 UVC lamps 2 lamp support clips 1 PCO filter and gloves Complete 2 Year Maintenance Kit DM900 1003 Contains 1 HEPA filter 4 carbon prefilters 2 UVC lamps 1 PCO filter 2 carbon potassium permanganate final filters gloves Dimensions Height Width Depth 29 5 in 16 25 in 12 75 in 74 9 cm 41 3 cm 32 4 cm Intake 14 5 x 3 75 in or 8 in dia 36 8 x 9 5 cm or 20 3 cm dia Outflow 14 5 x 4 37 i...

Page 8: ...bility are hereby limited in duration to the period for which the limited warranty is given The expressed warranties made in this warranty are exclusive and may not be altered enlarged or changed by any distributor dealer or other person whatsoever ELECTRO AIR CANADA WILL NOT BE RESPONSIBLE FOR 1 Normal maintenance as outlined in the Owner s Manual including cleaning and or replacement of filters ...

Reviews: