13
OZONE REDUCTION
All electronic air cleaners typically produce a small
amount of ozone that is within established limits.
Some customers may notice an odor especially at
high altitudes or low air flow rates.
This power supply has a “hairpin” shaped jumper
wire labeled W1 (see Fig 24) that can be cut and
separated in case of such complaints. This will
cause the power supply to limit the maximum
operating power to a lower level.
LINE
WHT/BRN
BLK
W1
E3
E2
Ozone Reduction Jumper
Cut and separate
Ozone Reduction
Jumper
Figure 24