MAINTENANCE

 

 
CLEANING   
 
ATTENTION: Please turn off the appliance and disconnect from the mains before cleaning or 
performing any maintenance. 
 
CLEANING THE SURFACE 

  Clean the plastic housing with a duster or a soft wet cloth.   

  Do not use chemical solvents (such as benzene, alcohol or gasoline) as they may cause irreversible 

damage.   

  Make sure no water enters the control panel. 

 

 

CLEANING THE WATER TANK   
 

 

  Unplug the appliance then remove the screws securing the filter frames. 

  Unfasten the water tank from the main body using the clasps on either side of the appliance. 

  Lift the filter frames to remove from the unit.   

  With a cloth (dipped in a mild detergent), wipe the water tank, rinse it with water.   

  Cleaning the water tank at least once a week will help reduce any mineral deposits and keep the 

filters clean. 

  Care should be taken with the water pump when the water tank is removed to avoid damage.   

  Do not run the unit in cooling mode with stale water in the tank.   

  We recommend emptying the tank and refilling it with fresh water if water has been standing in 

the tank for an extended period of time. 

 

Unfasten  the  water 
tank  using  the  two 
clasps on the side 

Water Tank 

Unscrew  the  screws 
holding  the  frame  in 
position 

Water Pump 

Lift  up  the  filter  frame 
and  remove  from  the 
unit. 

Summary of Contents for SLIM20I

Page 1: ...E COOLER Thank you for choosing electriQ Please read this user manual before using this innovative Air Cooler and keep it safe for future reference Visit our page www electriQ co uk for our entire ran...

Page 2: ...INSTRUCTIONS 3 FEATURES 4 HOW EVAPORATIVE AIR COOLERS WORK 5 DIAGRAM 6 INSTALLATION 6 CONTROL PANEL 7 OPERATION 7 REMOTE CONTROL 8 FILLING THE WATER TANK 8 MAINTENANCE 9 TROUBLE SHOOTING 11 APPENDIX 1...

Page 3: ...e appliance by a person responsible for their safety Do not leave children unsupervised with this appliance Do not clean the unit by spraying it or immersing it in water Never connect the unit to an e...

Page 4: ...tive humidity in the room exceeds 60 The ambient operating temperature range is from 5 C to 40 C If used in low temperatures as a humidifier it is recommended to fill the water tank with warm but not...

Page 5: ...ve humidity for optimum operation is 60 or lower A drier climate makes for more noticeable cooling The evaporative air cooler should not be used in enclosed or sealed spaces It must be kept level and...

Page 6: ...ure all parts are present and the unit is assembled correctly Ensure the clasps attaching the Water tank are secure WATER TANK Fill the water tank through the top water tank with water or ice ensuring...

Page 7: ...The Swing symbol will be illuminated when the function is active Press again to turn it off WHILE THE UNIT IS RUNNING Repeatedly press the timer button to select in how many hours the unit should turn...

Page 8: ...fore turning on the cooling function please add water to the tank The appliance can be used without water in air cleaner mode Before filling with water open the cover on the top of the appliance ensur...

Page 9: ...n either side of the appliance Lift the filter frames to remove from the unit With a cloth dipped in a mild detergent wipe the water tank rinse it with water Cleaning the water tank at least once a we...

Page 10: ...onths depending on your needs For best results allow the honeycomb filter to dry after each use by turning off the cooling function for 15 minutes with empty water tank before turning the unit off Unp...

Page 11: ...comb cooling media will have an odour which will dissipate within a week of use 2 Honeycomb filter may have developed mold or bacterial growth 1 No action required 2 Clean the filter pads with mild an...

Page 12: ...onday to Friday www electriQ co uk Unit J6 Lowfields Way Elland West Yorkshire HX5 9DA Model Number SLIM20I Description Symbol Value Unit Water Tank 18 Litres Voltage 220 240 V Frequency 50 Hz Power 2...

Reviews: