1. Installation 

 

Warning

Before using this unit, please keep it upright for at least 3-4 hours.   

This unit can easily be moved from one room to another. While moving the unit 
please note that it must always be kept upright and then placed on an even surface. 

 

1.

 

Place the venting hose on the exhaust air outlet at the back of the   
air conditioner. 

 
2.

 

Push it in then turn anti-clockwise. Make sure is fixed to the unit 
and does not come out. 

Note: Do not push too hard as this may cause damage. To screw it 
into place should take no less than three rotations 

 
3.

 

Extend one head of the hose and screw it 
into the unit anti-clockwise. In the same way 
connect the hose to the assembled adaptor (at least three rotations) 
 

4.

 

Installation of window kit:   
Partially open a window and then fix the   
window kit to the window as in the image.   

This method works with sash 
or vertical sliding windows. 
The window adapter can be placed 
both horizontally or vertically. It can 
be also installed using the trough the 
wall mounting adapter. 
See Venting the air conditioner section 
for other venting options. 
 
   

 

 
5.

 

Please make sure the venting hose is not 
kinked or bent. The operation of the unit 
will be affected if the air conditioner’s air- 
flow is obstructed.   

 
 
 
 
6. Make sure the unit is upright and vertical and there are 
no obstructions to the air inlets and outlet grills.   
We recommend allowing 50 cm around the unit for 
optimal operations and unrestricted airflow. 
Do not use in laundry rooms or areas where relative 
humidity is higher than 80%. 

Summary of Contents for PLAC12000HP

Page 1: ...MANUAL Thank you for choosing ElectrIQ Please read this user manual before using this innovative Air Conditioner and keep it safe for future reference Visit our page www electrIQ co uk for our entire...

Page 2: ...18 CONTENTS 1 SAFETY INSTRUCTIONS 3 2 FEATURES AND PARTS LIST 4 3 ACCESSORIES 6 4 INSTALLATION 7 5 VENTING 8 4 OPERATION AND SETTINGS 9 5 WATER DRAINAGE 14 6 MAINTENANCE 15 7 TROUBLE SHOOTING 16 8 AP...

Page 3: ...thorized service representative Failure to comply could result in a voided warranty Do not use the appliance for any other purposes than its intended use The air conditioner unit must always be stored...

Page 4: ...entering the machine LED screen indicates temperature and operation mode LCD Remote control with temperature function and follow me function On Off timer function allows you to choose when the unit op...

Page 5: ...ontrol panel 11 Drain port 3 IR receiver 12 Air outlet hot cold 4 Recessed handles 13 Lower air inlet filter frame 5 Front Panel 14 Drain heat pump model only 6 Air outlet 15 Power cord outlet 7 Remot...

Page 6: ...e A oval or type B round With window sider kit and bolt 1 set Wall exhaust adapter 1 piece Round adapter 1 piece or Nut and bolt or plastic locking bolt not supplied with all models 1 set Remote contr...

Page 7: ...nect the hose to the assembled adaptor at least three rotations 4 Installation of window kit Partially open a window and then fix the window kit to the window as in the image This method works with sa...

Page 8: ...ls to block the openings The best form of installation is through a wall duct We recommend that you use a self opening draft shutter if you use the wall ducting Please note that the unit will need to...

Page 9: ...indicator o FAN Fan only mode indicator o TIMER Timer on indicator o SLEEP Sleep mode indicator o SWING Swing mode indicator Note Some functions like swing sleep timer auto etc will need the LCD remot...

Page 10: ...for when the unit is started certain models 6 Speed Press this key to set low medium high fan speed 7 Sleep Press this key to enable sleep mode 8 Turbo One key setting to achieve maximum output 9 Swin...

Page 11: ...e unit is started a When the unit is on standby mode press CLEAN on the remote control the remote will show CL When the unit starts using the remote control the unit will run for maximum 35 minutes on...

Page 12: ...de press TIMER button the remote LCD displays TIMER ON and the timer is 0 5h to 24h Press set arrow up or down to adjust the time with and a step of 0 5 hrs from 0 5 10 hrs and 1 hr from 10 24 Press T...

Page 13: ...ly and P1 will flash on the LED screen Please discharge water in the machine according to Water Drainage instructions 3 3 Compressor delay protection Except for the first power on or when changing fro...

Page 14: ...Please ensure all three rubber bungs are in and secured if using the self evaporation function If the unit is vented correctly in cooling mode most of the water is reused to cool the condenser coil a...

Page 15: ...ers Open from here Please note If the optional active carbon filter is in use it should be changed every 2 3 weeks based on the environment The unit can be installed with HEPA filters but this may red...

Page 16: ...t after 5 minutes when compressor has cooled Remote control doesn t work Operating distance is too far Move remote control closer to the unit and make sure it aims at the air outlet grille Control pan...

Page 17: ...ing centres TECHNICAL DATA Capacity Cooling 3 5 kWh 12 000 BTU Heating 3 3 kWh 11 300 BTU Rated Input Cooling 1 34 kW Heating 1 18 kW Rated Current Cooling Heating 5 95 A 4 88 A Rated Input Cooling He...

Page 18: ...1057 or complete the online form 1 Has the unit been standing upright for at least 2 hours 2 Is the unit plugged into the mains 3 Is the fuse OK 4 Switch the unit off and wait three minutes to see if...

Reviews: