3.    Multi protective function 

 
3.1 Anti-freezing protecting control: 

When  the  ambient  temperature  is  low  while  in  Cooling  Mode,  the  compressor  and  water 

motor will stop working if the copper coil temperature reaches <2

 for over 20 seconds. When 

the copper coil temperature increases to >8

, the protection will be stopped automatically.   

3.2

Water-full protection: 

When  the  water  level  in  the  internal  water tank  is  surpassing the  maximum  level, the unit 

will alert automatically and “P1” will flash on the LED screen. Please discharge water in the 

machine according to “Water Drainage” instructions 

 

3.3 Compressor delay-protection   

Except  for  the  first  power-on,  (or  when  changing  from  Cooling  to  Heating  mode)  the 

compressor  can  start  instantly.  The  compressor  also  runs  under  a  3  minute  delay  protection 

function.   

 

3.4 Compressor protection 
 

In cooling, dehumidifying and heating mode, if the temperature difference between the 
coil temperature and room temperature is less than 3

, for more than 30 minutes, the 

machine will enter ‘no refrigerant’ compressor protection mode. The compressor and 
water pump motor will stop working. Normal operation will resume in due time. 

Summary of Contents for PLAC12000HP

Page 1: ...MANUAL Thank you for choosing ElectrIQ Please read this user manual before using this innovative Air Conditioner and keep it safe for future reference Visit our page www electrIQ co uk for our entire...

Page 2: ...18 CONTENTS 1 SAFETY INSTRUCTIONS 3 2 FEATURES AND PARTS LIST 4 3 ACCESSORIES 6 4 INSTALLATION 7 5 VENTING 8 4 OPERATION AND SETTINGS 9 5 WATER DRAINAGE 14 6 MAINTENANCE 15 7 TROUBLE SHOOTING 16 8 AP...

Page 3: ...thorized service representative Failure to comply could result in a voided warranty Do not use the appliance for any other purposes than its intended use The air conditioner unit must always be stored...

Page 4: ...entering the machine LED screen indicates temperature and operation mode LCD Remote control with temperature function and follow me function On Off timer function allows you to choose when the unit op...

Page 5: ...ontrol panel 11 Drain port 3 IR receiver 12 Air outlet hot cold 4 Recessed handles 13 Lower air inlet filter frame 5 Front Panel 14 Drain heat pump model only 6 Air outlet 15 Power cord outlet 7 Remot...

Page 6: ...e A oval or type B round With window sider kit and bolt 1 set Wall exhaust adapter 1 piece Round adapter 1 piece or Nut and bolt or plastic locking bolt not supplied with all models 1 set Remote contr...

Page 7: ...nect the hose to the assembled adaptor at least three rotations 4 Installation of window kit Partially open a window and then fix the window kit to the window as in the image This method works with sa...

Page 8: ...ls to block the openings The best form of installation is through a wall duct We recommend that you use a self opening draft shutter if you use the wall ducting Please note that the unit will need to...

Page 9: ...indicator o FAN Fan only mode indicator o TIMER Timer on indicator o SLEEP Sleep mode indicator o SWING Swing mode indicator Note Some functions like swing sleep timer auto etc will need the LCD remot...

Page 10: ...for when the unit is started certain models 6 Speed Press this key to set low medium high fan speed 7 Sleep Press this key to enable sleep mode 8 Turbo One key setting to achieve maximum output 9 Swin...

Page 11: ...e unit is started a When the unit is on standby mode press CLEAN on the remote control the remote will show CL When the unit starts using the remote control the unit will run for maximum 35 minutes on...

Page 12: ...de press TIMER button the remote LCD displays TIMER ON and the timer is 0 5h to 24h Press set arrow up or down to adjust the time with and a step of 0 5 hrs from 0 5 10 hrs and 1 hr from 10 24 Press T...

Page 13: ...ly and P1 will flash on the LED screen Please discharge water in the machine according to Water Drainage instructions 3 3 Compressor delay protection Except for the first power on or when changing fro...

Page 14: ...Please ensure all three rubber bungs are in and secured if using the self evaporation function If the unit is vented correctly in cooling mode most of the water is reused to cool the condenser coil a...

Page 15: ...ers Open from here Please note If the optional active carbon filter is in use it should be changed every 2 3 weeks based on the environment The unit can be installed with HEPA filters but this may red...

Page 16: ...t after 5 minutes when compressor has cooled Remote control doesn t work Operating distance is too far Move remote control closer to the unit and make sure it aims at the air outlet grille Control pan...

Page 17: ...ing centres TECHNICAL DATA Capacity Cooling 3 5 kWh 12 000 BTU Heating 3 3 kWh 11 300 BTU Rated Input Cooling 1 34 kW Heating 1 18 kW Rated Current Cooling Heating 5 95 A 4 88 A Rated Input Cooling He...

Page 18: ...1057 or complete the online form 1 Has the unit been standing upright for at least 2 hours 2 Is the unit plugged into the mains 3 Is the fuse OK 4 Switch the unit off and wait three minutes to see if...

Reviews: