ElectrIQ P12CE-V2 User Manual Download Page 12

Page 

12

 of 

15

 

 

MAINTENANCE 

 

CLEANING 

 

Please shut off the unit and unplug from the mains before cleaning or performing any 
maintenance

 

 

CLEAN THE SURFACE 

Clean the plastic housing with a duster or a soft wet cloth.   
Do  not  use  chemical  solvents  (such  as  benzene,  alcohol  or  gasoline)  as  they  may  cause 
irreversible damage.   

 
AIR FILTER CLEANING

 

a) 

Clean the air filters on the sides of the unit every 2 weeks. If the air filter is blocked with dust, 
the unit’s performance will be significantly affected.

   

b) 

Disconnect the power plug from the socket before dismantling, assembling or cleaning 

c) 

Open the air filter covers and remove the washable mesh filter 

d) 

Wash  the  mesh  air  filters  by  immersing  them  in  warm  (about  40

)  water  with  a  neutral 

detergent. 

e) 

Rinse it and then dry them thoroughly. 

f) 

Carefully re-install air filters back into their cover 

 
END OF SEASON MAINTENANCE

 

3. 

Pull out the plug from the drainage hole and empty the internal tank. You can also drain the 
water by leaning the unit. 

4. 

Then switch the unit to low fan mode.   

5. 

Keep the unit in this mode for half day - until the conduit is dried. Doing this helps to keep 
the inside of the unit dry and prevents mold developing 

6. 

Turn off the unit and pull out the plug. 

 

7. 

Coil the wire and bind it together, then put it into the accessories space. 

8. 

Separate the air-exhausted pipe and store it safely.

   

9. 

Cover the unit and keep it in a dry place. 

10. 

Take the batteries out of remote control and store, or dispose, them safely   

11. 

Keep all accessories with the unit ready for next season.

 

 
 

Summary of Contents for P12CE-V2

Page 1: ...TIONER Thank you for choosing electriQ Please read this user manual before using this innovative Air Conditioner and keep it safe for future reference Visit our page www electriQ co uk for our entire...

Page 2: ...e 2 of 15 CONTENTS SAFETY INSTRUCTIONS 3 FEATURES 5 DIAGRAM AND ACCESSORIES 6 INSTALLATION 7 OPERATION 9 REMOTE CONTROL 11 WATER DRAINAGE 11 MAINTENANCE 12 TROUBLESHOOTING 13 TECHNICAL DATA 14 SUPPORT...

Page 3: ...ance shall not be made by children without supervision Do not leave children unsupervised with this appliance Do not clean the unit by spraying it or immersing it in water Never connect the unit to an...

Page 4: ...Refrigerant gas may be odourless Do not use the product and contact the retailer for advice if damage has occurred to the unit which may have compromised the refrigerant system Any repairs or maintena...

Page 5: ...of the unit Enhanced design with hot air outlet positioned higher this allows for improved performance with the use of a short hose 24 hour programmable timer function allows you to choose when the un...

Page 6: ...VIEW LEFT VIEW FRONT VIEW RIGHT VIEW BACK VIEW Display Panel Air Inlet Power cable Handle Air Inlet Upper drainage port Lower Drainage port Slide bar Fishtail adaptor Exhaust hose FRONT VIEW Remote co...

Page 7: ...ng the fishtail into position At least 3 full rotations 2 Assemble the Exhaust hose connector on to the other end of the hose by extending the opposite end of the hose and twisting the outlet into pos...

Page 8: ...of window However the fish tail adaptor can be used with most windows doors When using the cooling mode ensure that the opening is left as small as possible The best form of installation is through a...

Page 9: ...oisture is extracted from the air that passes through the unit Continuous drainage should be set up for the moisture collected Drainage pipe not included FAN MODE No cooling effect circulates air with...

Page 10: ...Press the POWER button before the time has elapsed and the unit will turn on as normal and the timer will be cancelled 4 The function and fan speed can be set whilst setting the timer OFF TIMER The ti...

Page 11: ...l stop working and the TANK FULL light will illuminate 2 Shut off the unit and unplug Try not to move the model abruptly as this may cause water to spill out from internal water tank 3 Place a tray un...

Page 12: ...filters by immersing them in warm about 40 water with a neutral detergent e Rinse it and then dry them thoroughly f Carefully re install air filters back into their cover END OF SEASON MAINTENANCE 3...

Page 13: ...erature is lower than setting temperature Change the setting temperature The unit is loud The unit is not put on flat surface Put the unit on flat and hard surface Compressor does not work Overheating...

Page 14: ...ed during the recycling process so please be considerate when depositing your equipment Please contact the local council for details of your local household waste recycling centres TECHNICAL DATA Capa...

Page 15: ...form on our website or call 0871 620 1057 1 Has the unit been standing upright for at least 2 hours 2 Is the unit plugged into the mains 3 Is the fuse OK 4 Switch the unit off and wait three minutes...

Reviews: