NOTES:
The copper pipe used in the refrigeration lines is very soft, high pressure copper and prone
to get damaged if not handled correctly. Try to avoid getting it bent or stretched. Always use
foam protectors (sleeve) and a plastic ring before getting the pipes through the wall. Those
will help prevent damage to the pipes.
To keep the allowed
bending radius please
make the packed soft
pipes vertical before
Please do not extend only one side of
the packed soft pipes.
Please make use of
semicircle pulley to keepthe
allowed bending angle
Extreme bending could damage the pipes
Please use a twisting
wheel to avoid improper
bending.
Over bent soft pipes will lead to irregular
bending
Please use rigid elbow to
keep the bending angle
while soft pipes operating.
Undersize bending will damage the soft
pipe.
Please keep the minimum
bending angle while
installing
Do not use short sharp angle bends.