ElectrIQ eiQ-FC18K User And Installation Manual Download Page 18

18 

 

TOOLS RECOMMENDED FOR INSTALLATION 

 

 

Electric Drill 

 

Hammer 

 

Screwdrivers 

 

Tape Measure 

 

Core Hole Cutter 

 

Spirit Level 

 

Number 14 (7mm) 

Masonry Drill 

 

Pencil and Chalk 

 

1.5 inch number 10 

screws 

 

Small Stepladder 

 

7mm Wall Plugs 

 

Protective Glasses 

and Mask 

 

Pipe and Cable 

Detector 

 

4 inch Plastic Ties 

 

2 Inch Pipe Clips 

 

Circuit Breaker 

 

Garden Gloves 

 

Dust Sheets 

 

Foam Filler 

 

Silicone Sealant 

and gun 

Summary of Contents for eiQ-FC18K

Page 1: ...PUMP eiQ FC18K 18 000 BTU eiQ FC24K 24 000 BTU eiQ FC36K 36 000 BTU Thank you for choosing electriQ Please read this user manual before using this innovative Air Conditioner and keep it safe for futu...

Page 2: ...CONTROL 8 REPLACING THE BATTERIES 10 FILTERS 13 START OF SEASON 14 END OF SEASON 14 INSTALLATION GUIDE 15 TOOLS RECOMMENDED FOR INSTALLATION 18 INSTALLATION OF THE OUTDOOR UNIT 23 PIPELINES CONNECTION...

Page 3: ...not intended for use by persons including children with reduced physical sensory or mental capabilities It is also not intended for use by those with a lack of experience and knowledge unless they hav...

Page 4: ...ssary depending on the air quality For the initial startup set the fan speed to maximum and the thermostat to 4 5 degrees lower than the current temperature After set the fan switch to low and set the...

Page 5: ...ilter and over the evaporator 1 blowing the cooled air back into the room The heat is moved to the compressor along with the gas A fan 8 draws air over the condenser and blows the warm air away 1 Evap...

Page 6: ...6 ALTERNATIVE WAYS TO MOUNT CEILING MOUNTED FLOOR MOUNTED...

Page 7: ...mperatures the unit will enter defrost mode to prevent compressor damage and the compressor will heat for a while TIMER YELLOW Indicates the timer is active PROTECTION RED Fault protection mode may be...

Page 8: ...s on the remote CLOCK Press to adjust the current time LIGHT Dependant on Model Forced closing or lighting of display panel Decide whether to have this function according to the actual model HORIZONTA...

Page 9: ...ION FAN MODE ECON FUNCTION HEATING MODE CLEANING FUNCTION TEMPERATURE DISPLAY REMOTE LOCKED CURRENT TEMPERATURE Ranges between 16 32 C BATTERY LOW FAN SPEED AUTO CONFIG LENGTH OF BAR INDICATES FAN SPE...

Page 10: ...n pressing this button the desired temperature will be increased by 1 C When pressing this button in dehumidification and fan modes the desired temperature will not be adjusted 2 After the clock butto...

Page 11: ...set to 26 4 When ECON mode is turned off the desired temperature will return to the value before the button was pressed 5 Switching between modes will turn off ECON mode SLEEP 1 Sleep mode can be acti...

Page 12: ...the heat pump will degrade with lowering external temperatures Please note the performance will reduce when the outdoor temperature drops below 5 C CAPACITY The required cooling or heating capacity d...

Page 13: ...unit is cellingmounted pleaseensureenoughspaceis left to servicethe filters Identify the filters and remove them as per the procedure bellow Find the groove on the panel and pull the filter out When...

Page 14: ...intake and exhaust openings free of debris etc Cleaning with chemicals may cause damage Use professional installers to service the fan or the other parts START OF SEASON If the air conditioner is to b...

Page 15: ...nances and standards Check the mains voltage and frequency This unit is only suitable for earthed electrical supply connection voltage 230V 50 Hz The fuse used should be 1 5 3 times the maximum power...

Page 16: ...tioner must not be installed in a wet environment such as a bathroom shower or swimming pool etc Make sure that there is a minimum of 35 mm clearance in all directions A B C When outdoor unit is insta...

Page 17: ...or unit installation is made in respect to installation dimension diagram with easy maintenance access Select a place where it is out of reach of children Do not block utilities access or fire escapes...

Page 18: ...e Cutter Spirit Level Number 14 7mm Masonry Drill Pencil and Chalk 1 5 inch number 10 screws Small Stepladder 7mm Wall Plugs Protective Glasses and Mask Pipe and Cable Detector 4 inch Plastic Ties 2 I...

Page 19: ...esired length and then place it in the drilled hole CEILING MOUNTING The mounting surface should be solid brick concrete or other equivalent strength structure with sufficient loading capacity Failing...

Page 20: ...ipes drain pipes control and electrical wires before you permanently hang the indoor unit The installation steps for embedded style are basically the same with the hanging style but remove the left an...

Page 21: ...re of the ceiling set the thread pitch based on the size of this unit as bellow WOODEN STRUCTURES STEEL SKELETON STRUCTURES Place the square bar on the girders and install the lifting bolts Set direct...

Page 22: ...dity is very high Tidy up the copper pipes electrical cables and water drains and pass them through the piping wall hole drilled before Notes 1 Either the indoor unit or the outdoor unit can be higher...

Page 23: ...bolts and nuts to fix the outdoor unit firmly on the supports and keep on the same level If the unit is installed on the wall or at the rooftop the supports have to be firmly fixed so as to resist ear...

Page 24: ...24 FOOTPRINT OF THE OUTDOOR UNITS DIMENSIONS mm Unit eiQ FC18 A B C D E 925 366 700 590 340...

Page 25: ...25 DIMENSIONS mm Unit eiQ FC24 A B C D E F 958 392 843 600 360 330 DIMENSIONS mm Unit eiQ FC36 A B C D E F 1030 432 788 707 389 370...

Page 26: ...surface of the pipe against the connector vertically twist the connectors to the bottom of the bolt and finally tighten them with a torque wrench AIR PURGING WITH VACUUM PUMP 1 Check that pipelines c...

Page 27: ...ength This operation can only be performed by a professional F Gas engineer for the additional gas amount see the below Liquid pipe diameter Additional Refrigerant Additional Refrigerant 6 3 or 6 1 4...

Page 28: ...ipeline connection is done use a leakage inspection device to carefully check if there is any leakage at the joints This is an important step to ensure the quality of installation Once a leak is detec...

Page 29: ...ing radius please make the packed soft pipes vertical before Please do not extend only one side of the packed soft pipes Please make use of semicircle pulley to keepthe allowed bending angle Extreme b...

Page 30: ...ELECTRICAL WIRING DIAGRAMS For ease of installation the indoor unit of most models will be provided pre wired with 5 metres of interconnecting cable eiQ FC18K eiQ FC24K eiQ FC36K Indoor Unit Outdoor U...

Page 31: ...ON OF THE POWER CORD Supply the power to both indoor outdoor units following the wiring diagrams in this manual Where discrepancies are found between the diagram within the manual and the circuit diag...

Page 32: ...se sequence fault E0 Indoor and out unit communication failure E1 Timing lights flash Temperature sensor T1 fault E2 Running lights flash Pipe temperature sensor in the evaporator T2 fault E3 Running...

Page 33: ...rved Display Error description Display Error description P0 reserved H0 Communication error between outdoor unit main board and driver board P1 reserved H1 reserved P2 reserved H2 reserved P3 Primary...

Page 34: ...inverter current operating capacity factor adjusted from outdoor unit requirements T4 eiq FC18K 5 3kw eiq FC24K 7 1kw eiq FC36K 10 5kw eiq FC48K 14kw The kw is converted approximatively to hp in the...

Page 35: ...valve has 500 steps from close position The display will show from 0 20 to 60 500 which is the valve step divided by 8 12 Primary current AC Primary circuit load Amps 13 Secondary circuit current AC S...

Page 36: ...1400 1400 Insulation class E E Indoor coil Number of rows 2 3 Tube pitch a xrow pitch b Mm 21 13 37 21 13 37 Fin spacing Mm 1 4 1 4 Fin type Hydrophilic Hydrophilic Tube outside dia and type mm 7 7 i...

Page 37: ...min 1400 Insulation class E Indoor coil Number of rows 3 Tube pitch a xrow pitch b mm 21 13 37 Fin spacing mm 1 4 Fin type Hydrophilic Tube outside dia and type mm 7 inner grooved Coil length x heigh...

Page 38: ...This means that if your air conditioner develops a fault during the guarantee period we will arrange for it to be repaired or replaced Faults arising from a faulty installation are specifically exclud...

Page 39: ...our local household waste recycling centres WARNING Do not use means to accelerate the defrosting process or to clean other than those recommended by the manufacturer The appliance shall be stored in...