FEATURES 

Your dehumidifier belongs to the electriQ dehumidifier range featuring power saving logic. 
   

1. 

Easy to use controls  

2. 

Cost effective way to combat mould, condensation and damp  

3. 

Optional HEPA and Carbon filters for air purification 

4. 

UV light and Ioniser to remove mould and pathogens from the air. 

5. 

Dries laundry more efficiently than a tumble dryer   

6. 

Designed to complement any modern space  

7. 

Castors for improved mobility  

8. 

Intelligent CPU controlled digital humidistat with 35-80% RH and room humidity display  

9. 

24 hours start / stop timer  

10.  Tank operation or permanent drainage option with splash proof tank  
11.  Tank full alarm & auto-stop function  
 

These dehumidifiers use compressor technology to extract water from the environment. Compressor 

dehumidifiers are ideal for normal domestic or office environments which are heated during the winter 

months and maintain a temperature above 12-

15⁰C.  

 

This dehumidifier is easy to move around on castors and is designed to extract unwanted humidity while 

saving money due to 

it’s power saving logic. It features an intelligent humidistat where the desired relative 

humidity can be adjusted in increments of 5% between 35 and 80% ensuring the air in your room is not too 

dry and that power is not wasted.  

 

INSTALLATION 

Remove any water from within the water tank before starting the unit. In order to save energy do not open 

windows or doors while the unit is running. Place the unit on a hard / flat surface. On first use run the unit 

continuously for 24 hrs.  

 
TO REDUCE NOISE LEVELS: 

Place a piece of carpet or a rubber mat under the unit to reduce any 

vibrations while the unit is running.  

 

FITTING THE OPTIONAL FILTERS 

The optional filters can be placed in the appliance before use. The optional HEPA filter is fitted into the rear 

of the filter housing. The optional Carbon filter is placed between the unit and the filter housing. 

 

 
 

 

Unclip the filter 

housing. 

Remove the filter 

housing and fit the 

HEPA filter.  

(If required) 

Refit the filter 

housing and place 

the Carbon filter in 

position.  

(If required) 

Ensure the filter 

housing is securely 

fastened into 

position. 

Summary of Contents for CD12LE

Page 1: ...LEB 12 Litres per day CD20LE CD20LEB 20 Litres per day Thank you for choosing electriQ Please read this user manual before using this innovative dehumidifier and keep it safe for future reference Visi...

Page 2: ...UTANTS 4 APPLIANCE DIAGRAM 5 FEATURES 6 INSTALLATION 6 FITTING THE OPTIONAL FILTERS 6 CONTROL PANEL 7 OTHER FEATURES AND INDICATORS 9 QUICK REFERENCE GUIDE 10 POSITIONING THE DEHUMIDIFIER 11 WATER DRA...

Page 3: ...tlet using an extension cord If a power outlet is not available one should be installed by a qualified electrician Never operate this appliance if the power cord or plug is damaged Ensure the power co...

Page 4: ...ized engineer must be in possession of a copy of the manufacturer s service manual and must follow the safety information contained within it to ensure all hazards are minimized The refrigerant system...

Page 5: ...tants include bacteria viruses dust mites and pollen Emissions from electronic office equipment Many studies including those from EPA and the University of California Berkley have reported that emissi...

Page 6: ...Replacement filters are available from the retailer under code ACFIL CDLEX HEPA FILTER Filters are available from the retailer under code HEPA CDLEX Note Diagrams are for illustrative purposes only T...

Page 7: ...astors and is designed to extract unwanted humidity while saving money due to it s power saving logic It features an intelligent humidistat where the desired relative humidity can be adjusted in incre...

Page 8: ...continuously at high fan speed to remove the most moisture possible This is ideal for drying clothes UP DOWN HUMIDITY SETTING Press the UP and DOWN buttons to select the desired relative humidity lev...

Page 9: ...ions to improve indoor air quality The relevant LEDs above the button will illuminate to show which function is currently activated LOCK Press and hold the FUNCTION button for 3 seconds to activate th...

Page 10: ...oom with a temperature between 12 C and 20 C it will enter the defrost mode roughly every 45 minutes HUMIDISTAT CONTROL AND FAN COMPRESSOR OPERATION When the humidity of the room is 2 lower than the d...

Page 11: ...e fan moves the air around the room ensuring the entire air in the room is processed and humidity correctly measured DEHUMIDIFY MODE This is the standard operating mode for which the desired humidity...

Page 12: ...n for your dehumidifier If possible leave interior doors ajar to allow air circulation Alternatively if you have a serious problem in one area you can begin by positioning the dehumidifier there and m...

Page 13: ...into the unit Banging the bucket against anything or failing to push it in securely into place may cause the unit not to operate Do not remove any parts from the water tank or tank enclosure The water...

Page 14: ...over gently approximately every 2 3 weeks If the mesh filter is dirty hoover it if it is heavily soiled wash it with warm soapy water and dry thoroughly before reinserting it in the unit When filter c...

Page 15: ...re a distance of at least 20 cm between the unit walls Airflow seems weak Are the filters dirty or clogged Please service the filters regularly as per the user manual Unit is noisy during operation Is...

Page 16: ...unit may be defrosting The ambient operating range is between 5 C and 35 C with a relative humidity ranging from 30 to 80 For maximum efficiency use the unit between 15 C and 32 C Sometimes cold and...

Page 17: ...to operate call 0330 390 3061 or complete the online form Office hours 9AM 5PM Monday to Friday Unit J6 Lowfields Business Park Lowfields Way Elland West Yorkshire HX5 9DA Recycling facilities are no...