ElectrIQ AC60E User Manual Download Page 3

 
 

Page 

3

 of 

9

 

 

SAFETY INSTRUCTIONS 

IMPORTANT! 

  Carefully read the instructions before operating the unit 

  This appliance is for indoor use only. 

  Rating: This unit must only be connected to a 220-240 V / 50 Hz earthed outlet. 

  Installation must be in accordance with regulations of the country where the unit is used. 

  If you are in any doubt about the suitability of your electrical supply have it checked and, if 

necessary, modified by a qualified electrician. 

  This air cooler has been tested and is safe to use. However, as with any electrical appliance - 

use it with care.   

  Disconnect the appliance from the power socket before changing filters, dismantling, 

assembling or cleaning. 

  Avoid touching any moving parts within the appliance. 

  Never insert fingers, pencils or any other objects though the guard.   

  This appliance is not intended for use by persons (including children) with reduced physical, 

sensory or mental capabilities. It is also not intended for use by those with a lack of experience 
and knowledge, unless they have been given supervision or instruction concerning the use of 
the appliance by a person responsible for their safety. Do not leave children unsupervised with 
this appliance. 

  Do not clean the unit by spraying it or immersing it in water. 

  Do not operate the appliance with wet hands.   

  Never connect the unit to an electrical outlet using an extension cord. If an outlet is not 

available, one should be installed by a qualified electrician. 

  Never operate this appliance if the cord or plug is damaged. Ensure the power cord is not 

stretched or exposed to sharp objects/edges. 

  A damaged supply cord should be replaced by the manufacturer or a qualified electrician in 

order to avoid a hazard. 

  Any service other than regular cleaning or filter replacement should be performed by an 

authorized service representative. Failure to comply could result in a voided warranty. 

  Do not use the appliance for any purpose other than its intended use. 

  Never use the mains plug as a switch to start and stop the air cooler. Use the provided 

ON/OFF button located on the control panel. 

  Always place the unit on a dry and stable surface. Do not move or tilt the unit when the water 

tanks are full. 

  The appliance should not be installed in laundry or wet rooms.   

  Do not use this unit in environments with flammable or explosive gases. 

  Avoid keeping the unit in direct sunlight for a long period of time.

 

 

Energy Saving and Unit Safety Protection Tips 

  Do not cover or restrict the airflow from the outlet or inlet grills. 

  For  maximum  performance  the  distance  between  the  unit  and  a  wall  or  objects  should  be  at  least 

50cm.   

  While  in  operation,  ensure  that  the  level  of  the  water  tank  does  not  exceed 

MAX

  and  does  not  fall 

below 

MIN

  Keep  the  filters  clean.  Under  normal  conditions,  filters  should  only  need  cleaning  once  every  three 

weeks  (approximately).  Since  the  filters  remove  airborne  particles,  more  frequent  cleaning  may  be 
necessary, depending on the air quality. 

  In  order  to  achieve  maximum  efficiency  the  unit  should  be  placed  near  an  open  door  or  window. 

Evaporative Air Coolers work with an evaporative cooling mechanism which requires cross ventilation. 

  This unit will lose efficiency if the relative humidity within the room exceeds 60%.   

  The ambient operating temperature range is from 5°C to 40°C.   

If used in low temperatures (as a humidifier) it is recommended to fill the water tank with warm (but not 
hot) water. 

Summary of Contents for AC60E

Page 1: ...UMIDIFIER AC60E Thank you for choosing electriQ Please read this user manual before using this innovative Air Cooler and keep it safe for future reference Visit our page www electriQ co uk for our ent...

Page 2: ...age 2 of 9 CONTENTS SAFETY INSTRUCTIONS 3 FEATURES AND OPERATION 4 PARTS LIST AND INSTALLATION 5 CONTROL PANEL AND SETTINGS 6 REMOTE CONTROL 7 CLEANING AND MAINTENANCE 7 TROUBLE SHOOTING 8 APPENDIX 7...

Page 3: ...rd should be replaced by the manufacturer or a qualified electrician in order to avoid a hazard Any service other than regular cleaning or filter replacement should be performed by an authorized servi...

Page 4: ...ION The air cooler cools the air by means of evaporation When water evaporates into the air the result is a mixture of air and water molecules This chemical change requires heat which is taken from th...

Page 5: ...t you can put ice or the charged ice packs into either water tank but be sure that by adding ice or icepacks the water level does not go over the MAX limit Empty some water if necessary via the drain...

Page 6: ...n 7 hours is selected If the timer lights are off the timer is not activated Please note These are single use timers and cannot be combined or automatically repeated Shutdown timer While the air coole...

Page 7: ...clean Do not run the unit in Humidify mode with stale water in the tank We recommend emptying the tank and refilling it with fresh water if water has been standing in the tank for an extended period o...

Page 8: ...ll have an odour which will dissipate within a week of use 2 Honeycomb filter may have developed mould or bacterial growth 1 No action required 2 Clean the filter pads with mild antibacterial solution...

Page 9: ...onday to Friday www electriQ co uk Unit J6 Lowfields Way Elland West Yorkshire HX5 9DA Model Number AC60E V2 Description Symbol Value Unit Water Tank 6 Litres Voltage 220 240 V Frequency 50 Hz Maximum...

Reviews: