ElectrIQ 1535026 User Manual Download Page 7

 

NOTES:   

 

• 

The window kit is only designed to be installed with sliding or sash windows or doors. The window 
kit is not designed to be used with any other style of windows.  

 

• 

The fish tail adaptor can be used without the slide bar with most windows / doors.  

 

• 

When using the air conditioner ensure that the opening around the fishtail adaptor is as small as 
possible to ensure the efficiency of the unit is not reduced.  

 

• 

The best form of installation is through a wall duct. By properly venting you expel hot air from your 
room while efficiently cooling it. 

 

• 

Your air conditioner should be used without the vent pipe in dry mode. When using dry mode 
ensure that an external water tank is used, monitored and regularly emptied before overflowing. 
Permanent plumbing can be also installed or an external uplift water pump can be set up to allow 
for uninterrupted use.

 

 

IMPORTANT SAFEGUARDS   

The length of the soft hose extends from approximately 30 cm to 180 cm. If hose is extended above this 
length, the unit may malfunction which can invalidate the warranty. The outlet vent must be well 
ventilated and not obstructed as this will cause the unit to overheat. Keep the hose as straight and short 
as possible and avoid bending the air hose by more than 30 degrees in order not to reduce the 
performance of the unit. 

 

 

 

Summary of Contents for 1535026

Page 1: ...ECOSILENT8WE ECOSILENT10W 10 000 BTU ECOSILENT10WE Thank you for choosing electriQ Please read this user manual before using this innovative Air Conditioner and keep it safe for future reference Visi...

Page 2: ...REMOTE CONTROL 9 WIFI APP CONTROL 10 SETTING UP THE APP 10 CONNECTING THE AIR CONDITIONER 12 CONTROLLING YOUR DEVICE 14 SMART SCENES 17 CLEANING AND MAINTENANCE 20 EMPTYING THE INTERNAL WATER TANK 21...

Page 3: ...th this appliance Do not clean the unit by spraying it or immersing it in water Never connect the unit to an electrical outlet using an extension cord If an outlet is not available one should be insta...

Page 4: ...ised the refrigerant system Any repairs or maintenance must only be carried out on the unit by a suitably qualified engineer Before opening and servicing the unit the authorised engineer must be in po...

Page 5: ...oved Energy Efficiency 24 Hours Start Stop Timer Digital Thermostat Smart WIFI App control Castors and Handles for Enhanced Portability Auto Restart to retain the settings in the event of power failur...

Page 6: ...t outlet on the rear of the appliance by putting into position and twisting to lock in place 3 Make sure the unit is upright and there are no obstructions to the air inlets and outlet grills INSTALLAT...

Page 7: ...our air conditioner should be used without the vent pipe in dry mode When using dry mode ensure that an external water tank is used monitored and regularly emptied before overflowing Permanent plumbin...

Page 8: ...cannot be changed in SMARTCOOL and DRY modes Press to enter sleep mode The sleep indicator will be illumined and all other indicators will be turned off In sleep mode the appliance works at low fan s...

Page 9: ...ll enter auto defrost and the heating symbol will flash on the control panel AUTOMATIC THERMAL PROTECTION To protect the service life of the machine the machine has automatic thermal protection If the...

Page 10: ...OR SETUP The air conditioner has two different setup modes EZ Quick Connection and AP Access Point The quick connection is a quick and simple way to set the unit up The AP connection uses a direct loc...

Page 11: ...mail address or phone number and press continue to register 4 A verification code will be sent by the method selected in step 3 Enter the code into the app 6 The app is now registered It will automati...

Page 12: ...p 2 Select the type of device as Air Conditioner WIFI within the Large Home Appliance tab 3 Select your network enter your WIFI password and press Next 4 Ensure the WIFI light on the air conditioner i...

Page 13: ...Ensure the WIFI light on the air conditioner is slowly flashing once per three seconds then select AP Mode in the top right corner before pressing on the orange button at the bottom of the screen to...

Page 14: ...Allows you to program intelligent behaviour based on the internal and external environment Add Device Add a device to the app and go through the setup process Profile Provides the option for changing...

Page 15: ...desired temperature Current Room Temperature Displays the current room temperature Back Returns to the Home Screen Desired Temperature Shows what temperature the unit is currently set to MODE Change t...

Page 16: ...g the ADD ANOTHER ROOM option at the bottom See ADD ANOTHER ROOM below 5 Untick any rooms that are not required on the app 6 Press DONE in the top right corner SETTING YOUR LOCATION ADD ANOTHER ROOM U...

Page 17: ...ing the user to easily change between a number of preset configurations Below is an example of how to set up a scene 1 Press on the Smart Scene tab at the bottom of the Home screen 3 Select the type o...

Page 18: ...o add a smart scene 3 Select the type of automation required such as on schedule for setting up a timed operation 5 Chose the function set the value for the function and then press the back button in...

Page 19: ...ROUBLESHOOTING 1 Check whether the device is powered on and is in the correct WIFI connection mode if not please refer to the CHANGING BETWEEN CONNECTION MODES section on page 12 2 Ensure the WIFI pas...

Page 20: ...d once every two weeks or as often as necessarily in your environment CLEAN THE UPPER FILTER SCREEN FRAME Grip the edge of the evaporator filter screen frame with both hands Pull out to remove the fil...

Page 21: ...ter tank in cooling mode If the unit is vented correctly most of the water is reused to cool the condenser coils and any excess is evaporated Please do not use continuous drainage if you intend to use...

Page 22: ...ce Put the air conditioning on a flat and hard place to reduce noise Compressor does not work Overheat protection starts Wait for 3 minutes until the temperature is lowered and then restart the machin...

Page 23: ...triQ co uk support Please for your own convenience make these simple checks before calling the service line If the unit still fails to operate call the number below or complete the online form 0330 39...

Page 24: ...nt R290 280g R290 220g Sound power level 61dB A Thermostat 17 30oC Maximum working pressure of suction exhaust side 1 0 3 5MPa Maximum Allowable Pressure 3 5Mpa Power Supply AC 220 240V 50Hz Net Weigh...

Reviews: