USER INSTRUCTIONS

1. General

Unlike  other  system  boilers  such  as  Gas,  Oil  and  Propane  the 

FUSION ‘Comet’ range of electric boilers require no ignition or 

lighting sequence to be executed by the end user. All the end user 

is required to do is ensure that the system is filled with water and 

the room thermostat or programmer is calling for heat.

2. Boiler Operation

2.1 Switch the boiler on by pressing the 

 button. (Note: When 

switching the boiler off use the same 

 button by pressing 

and holding it in for 3 seconds.)

2.2 The recommended Water Pressure is approx 1.0/1.5 bar and 

this can be checked by pressing the 

 button until indicator 

A is illuminated. The water pressure can be adjusted by con-

necting the external filling loop and pressurizing to the desired 

pressure. Note: the filling loop must be disconnected after the 

system has been re -pressurized.

2.3 First set the required Boiler Temperature (we recommend a 

setting of 65 

0

C) by pressing the 

 button until only indicators 

D and K are illuminated. Press the 

 button or the 

 button 

until the desired temperature setting is achieved. 

2.4 Ensure the room thermostat is switched on and is calling for 

heat.  If  the  boiler  is  not  yet  at  the  desired  heat  setting  then 

indicators D, G, H, I, J & K will be illuminated with indictor K 

illuminated in red. Once the room has reached the required 

setting the K indicator should change from red to green. Refer 

to the Control Panel diagram above to learn how to adjust to 

the right temperature to make the boiler work comfortably and 

economically.

2.5 The boiler Flow Rate is set at 8 l/min during the installation 

of the boiler. To check this setting then press the 

 button a 

number of times until only indicator B is illuminated and then 

read the figure on the digital display. If the figure is well below 

the 8 l/min figure then call a Service Engineer for assistance.  

2.6 To check the amount of kW energy being used by the boiler at 

any point in time then press the 

 button a number of times 

until only indicator C is illuminated and then read the figure 

on the digital display. 

2.7 When indicator H is illuminated the pump is running 

3. Temperature Setting

We recommend the boiler temperature be set to 65

0

C. Raise or 

lower  the  temperature  in  your  installation  with  the  buttons  on 

the right hand side of the control panel as per 2.3 in the previous 

section.

    

ATTENTION:  Should the temperature on the front panel be set 

too low the desired room temperature may not be achieved.’

4. Summer Setting. (‘Stand by’ Mode)

The  customer  has  the  option  to  switch  the  boiler  onto  ‘stand-

by’ mode during summer months and this can be carried out by 

pressing the 

 “button and holding this in for 3 seconds.’

All indicators will go off except the F indicator which will inter-

mittently illuminate.  

IMPORTANT  -  DO  NOT  SWITCH  THE  BOILER  OFF  AT  THE 

MAINS SWITCH  

In the ‘stand-by’ mode all the boiler functions are switched off ex-

cept the circulation pump. This is activated for 15 minutes each 

day which protects the boiler and the whole central heating sys-

tem from being blocked and silted up.  In this ‘stand by’ mode the 

circulation pump will run each day at the same time. (e.g. If you 

switch the boiler to ‘stand by’ at 6pm then the circulation pump 

will run every day at 6pm for 15 minutes) To return to a ‘Winter’ 

mode  setting  then  press  and  hold  the 

  button  for  3  seconds 

again.

5. Winter mode

In the Winter mode setting the digital display will be active and 

will show the temperature of the water at various points within 

the boiler. Those indicators which are illuminated will show the 

current status of the boiler. If the boiler is being called for heat 

by the thermostat then the G, H, I, J & K indicators will be illumi-

nated. In the winter mode both the two port valves are active and 

they will direct heat as required.

Note:  When  in  diagnostic  mode  of  the  Display  (i.e.  using  the 

arrow  buttons),  and  there  has  been  no  activity  (i.e.  buttons 

pressed)  for  60  seconds  the  Display  will  revert  to  its  normal 

mode. 

 

 

Summary of Contents for EHCCOM12KW

Page 1: ...ate solution for central heating INSTALLATION TECHNICAL MANUAL If you require any further assistance Telephone 01698 820533 Fax 01698 825697 E mail info electric heatingcompany co uk or visit our website www electric heatingcompany co uk ...

Page 2: ......

Page 3: ...er leaks into the boiler All plumbing joints must be checked The warranty card must be completed and sent back to The Electric Heating Company as soon as possible for registration An internal Magnetic Filter is fitted to the Boiler and it must be cleaned at least annually Note Failure to clean the Magnetic Filter may result in boiler shutdown Warranty calls will not be covered for this repair This...

Page 4: ...ovide an adequate fixing and should be fitted in a location that the boiler and pipe work are not subject to frost and damp conditions 3 Central heating design installation Detailed recommendations are given in BS EN 12828 2003 BS 6700 2006 A1 2009 and CP 342 2 1974 Pipes forming part of the useful heating surface should be insulated to prevent any potential heat loss or frost damage BS 6700 1997 ...

Page 5: ...Btu s should be made to the space heating calculation 7 Insulation Where practical and if at all possible we recommend that all pipe work be insulated in particular the primary pipe work with in a boiler cupboard This is to reduce heat loss and reduce high cupboard temperatures from exposed pipe work BS 6700 2006 A1 2009 8 System Design The boiler has an integral automatic bypass valve fitted whic...

Page 6: ...rculating Pump 6 Safety Temperature limiter 7 Return connection 8 Flow connection 9 Power Board 10 Control Module 11 Automatic Vent 12 Expansion Vessel and connection 13 By pass Valve 14 Magnetic Filter PF Internal mains phase connections from the PN connection block PN Incoming mains cable connection block WP Electric cable access M Boiler fixing points RP Room Thermostat volt free connection ...

Page 7: ...re all drain cocks are fully open and that the system is completely drained 2 Add Fernox Heavy Duty restorer through the header tank or via filling loop at the recommended dose One bottle must be used as a minimum per dwelling If you are unsure of the cor rect dose rate contact Fernox 3 Re fill the system and circulate the Heavy Duty Restorer prior to the boiler being fired up then commission the ...

Page 8: ...8 GB 031C f 347 Temporary Filling Loop Mains Water Supply Temporary Filling Loop Mains Water Supply INSTALLATION Figure 5 Figure 4 ...

Page 9: ...DANCE WITH CURRENT IEE BS7671 WIRING REGULATIONS ALL ELECTRICAL CONNECTIONS MUST BE MADE BY A QUALI FIED TRADESPERSON A load check should be carried out to ensure that there is a sufficient current and voltage for the intended boiler installation Consideration should be taken into account with regard to the remainder of the properties load requirements All boilers must be protected at the meter po...

Page 10: ...led sys tems At this point the main power may be switched on At this stage you may carry out the cleansing and protection of the system Refer to the installation section of this manual See page 7 Programmer Stat Connections The boiler PCB has a voltage free connection for the controls RP NA Under no circumstances should 240V be connected to these controller block connections as this will damage th...

Page 11: ...11 GB 031C f 347 EHC SELECT 107XL PROGRAMMER TLX4101 ROOM THERMOSTAT CONTROL CONNECTIONS CONTROL CONNECTIONS EXTERNAL CONTROL WIRING Figure 8 Figure 9 ...

Page 12: ...r connection Optional Figure 10 SAFETY NOTE RP Tzas and NA are signal conductors only DO NOT CONNECT ANY VOLT AGE to these as this will damage the boiler and invalidate the boilers warranty Tzas connections not used ZTD connections not used Room Thermostat ...

Page 13: ...13 GB 031C f 347 EXTERNAL BOILER WIRING BOILER DIMENSIONS Figure 11 Return Inlet Flow Outlet Figure 12 ...

Page 14: ...n external boiler interrupt active P Pump Indicator on pump is active proper flow rate of water has been reached Flickers lack of flow or insufficient flow rate of water heating elements are off Temperature Indicator Red light Boiler is in heating mode Green light Boiler temperature has been reached in radiators A Indicator flickers water pressure is not sufficient below 0 5 bar F When boiler is i...

Page 15: ...e amount of kW energy being used by the boiler at any point in time then press the button a number of times until only indicator C is illuminated and then read the figure on the digital display 2 7 When indicator H is illuminated the pump is running 3 Temperature Setting We recommend the boiler temperature be set to 650 C Raise or lower the temperature in your installation with the buttons on the ...

Page 16: ...available at Pump head if power available replace as necessary If power not available check fuse on Controller Module and replace if necessary Flow sensor not operating Check the flow sensor and replace as necessary G indicator is flashing but boiler digital display operating NA connection open circuit Ensure NA connection is closed or if using external control e g Shower Sensor that this is worki...

Page 17: ... flow return pipes 22 mm Min water pressure 1 bar Max water pressure 3 bar Expansion vessel 6 lt Maximum system water volume about 60 litres at initial system pressure 1 5 bar Vessel charge pressure 1 5 bar Safety Class IP22 Dry weight 25kg Electrical supply 230V 1ph 50Hz 415V 3ph 50Hz Load current 26 0 Amp 39 1 Amp 52 2 Amp 62 6 Amp 3 x 34 8 Amp Recommended diameter of mains cable 10mm 16mm 10mm ...

Page 18: ......

Page 19: ......

Page 20: ......

Reviews: