![Electra LEX 25 DCI Service Manual Download Page 21](http://html1.mh-extra.com/html/electra/lex-25-dci/lex-25-dci_service-manual_2378858021.webp)
6-1
PRESSURE CURVES
Revision Y06-01
Service Manual - WNG/LEX DCI
6. PRESSURE
CURVES
6.1
Model: WNG 25/LEX 25 DCI
6.1.1
Cooling - Test Mode
500
600
700
800
900
1000
1100
1200
1300
1400
10
15
20
25
30
35
40
45
Su
ct
io
n
P
ress
ur
e
[k
P
a
]
22/15
24/17
27/19
29/21
32/23
Suction Pressure VS. Outdoor Temp'
Indoor DB/WB
Temp.
Outdoor Temp.(°C DB)
1000
1250
1500
1750
2000
2250
2500
2750
3000
3250
3500
3750
4000
10
15
20
25
30
35
40
45
D
ischar
ge
Pr
essur
e
[k
Pa]
22/15
24/17
27/19
29/21
32/23
Indoor DB/WB
Temp.
Discharge Pressure VS. Outdoor Temp'
Outdoor Temp.(°C DB)