2-3
PRODUCT DATA SHEET
Revision Y05-01
Service Manual - EMD Series
Model (Indoor & Outdoor)
EMD 35 & OU8-33 RC R22
Installation method
Ducted
Characteristics Units
Cooling
Heating
Btu/Hr 32500
34800
Capacity
Kw 9.5
10.1
Power input
Kw
3.3
2.9
COP W/W
2.87
3.53
Power supply
V/Hz/Ph
230V/50Hz/1PH
Rated current
A
14.4
12.3
Starting current
A
76
Circuit breaker rating
A
20
Fan type & quantity
Centrifugal & 1
Fan speeds
H/ M/ L
RPM
890
800
680
Air flow
*
H/
M/
L
M³/Hr
1770 1570 1300
External static pressure
Min-Max
Pa
37 - 80
Sound power level
**
H/
M/
L
dBa 68.2
65.5
61.3
Sound pressure level
***
H/
M/
L dBa
54.3
51.5
48.5
Moisture removal
Lt/Hr
2.7
Condensate drain tube I.D
mm
19
Dimensions
W/ H / D
mm
785
400
595
Weight Kg
36
Package dimensions
W/ H / D
mm
825
425
610
Package weight
Kg
38
Units per pallet
Units
8
INDOOR
Stacking height
Units
4
Refrigerant control
Capillary tube
Compressor type
Scroll
Fan type & quantity
Axial & 1
Fan speeds
H / L
RPM
850
Air flow
H / L
M³/Hr
3110
Sound power level
H / L
dBa
69
Sound pressure level ***
H / L
dBa
62
Dimensions
W/ H / D
mm
900
860
340
Weight Kg
78
Package dimensions
W/ H / D
mm
985
900
410
Package weight
Kg
82
Units per pallet
Units
6
Stacking height
Units
2
Refrigerant type
R22
Charge / Distance
Kg/ M
2.33 / 7.5
Additional charge per 1 meter
Grams
25
Liquid line
Inch
3/8
Suction line
Inch
5/8
Max. tubing length
Meter
30
OUTDOOR
Connections
between
units
Max. height difference
Meter
10
Operation control type
LCD Remote control
Heating elements
Kw
No
Others
Crankcase heater (60W)
*
Airflow in ducted units; according to nominal external static pressure.
** Sound power in ducted units is measured at air outlet side.