11-13
CONTROL SYSTEM
Revision Y05-01
Service Manual - Delta DCI
11.13 SW
Parameters
11.13.1
Indoor Units SW Parameters
General Parameters for All Models:
Parameters defining the indoor fan speed as a function of Indoor Coil temperature in heat mode
(ICT):
ICTST Speed
ICT to stop indoor fan
25
ICTVLSpeed
ICT to go down to very low speed
28
ICTLSpeed
ICT to start in very low speed
30
ICTHSpeed
ICT to start in increase speed from very low
32
ICTTSpeed
ICT to enable Turbo fan speed
40
Parameters for defrost protection:
ICTDef1
ICT to go back to normal
8
ICTDef2
ICT to ‘stop rise’ when ICT decrease
6
ICTDef3
ICT to ‘stop rise’ when ICT is stable
4
ICTDef4
ICT to ‘Hz Down’ when ICT decrease
2
ICTDef5
ICT to ‘Hz Down’ when ICT is stable
0
ICTDef6
ICT to stop compressor
-2
Parameters for indoor coil over heating protection:
ICTOH1
ICT to go back to normal
45
ICTOH2
ICT to ‘stop rise’ when ICT increase
48
ICTOH3
ICT to ‘stop rise’ when ICT is stable
52
ICTOH4
ICT to ‘Hz Down’ when ICT increase
55
ICTOH5
ICT to ‘Hz Down’ when ICT is stable
60
ICTOH6
ICT to stop compressor
62
Model Depended Parameters:
Parameter name
Models
22
25
35
NLOAD limits as a function of selected indoor fan speed
MaxNLOADIF1C
40
40
40
MaxNLOADIF2C
55
51
55
MaxNLOADIF3C
120
90
90
MaxNLOADIF4C
127
127
127
MaxNLOADIF5C
127
127
127
Indoor Fan speeds
IFVLOWC
700
700
700
IFLOWC
800
850
850
IFMEDC
950
1050
1000
IFHIGHC
1050
1200
1200
IFTURBOC
1150
1250
1250
IFVLOWH
700
700
700
IFLOWH
850
950
950
IFMEDH
1000
1050
1100
IFHIGHH
1100
1250
1250
IFTURBOH
1200
1350
1300
Nominal Compressor Frequency
NomLoadC
40
51
61
NomLoadH
55
58
62
Summary of Contents for DELTA 25
Page 56: ...ENGLISH AIR CONDITIONER SPLIT WALL MOUNTED PROGRAMMING AND OPERATING...
Page 68: ...P R O G R A M M I N G A N D O P E R AT I N G M A N U A L REMOTE CONTROL ENGLISH...
Page 69: ......
Page 70: ......
Page 71: ......
Page 72: ......
Page 73: ......
Page 74: ......
Page 75: ......