2-3
PRODUCT DATA SHEET
SM ASP 1-E.2 GB
2.3
Alpha 9 SP EU R410A / CSP 9 EU R410A
Model Indoor Unit
ASP 9 R410A flat for EU
Model Outdoor Unit
CSP 9 R410A for EU
Installation Method of Pipe
Flared
Characteristics
Units
Cooling Only
Cooling
Heating
Capacity
(4)
Btu/hr
8700
8700
9040
kW
2.55 2.55
2.65
Power input
(4)
kW
0.89
0.89
0.82
EER (Cooling) or COP(Heating)
(4)
W/W
2.84 2.84
3.22
Energy efficiency class
C
C
C
Power supply
V
220-230
Ph
1
Hz
50
Rated current
A
4.0
4.0
3.7
Power factor
W
0.97
0.97
0.97
Prated(IDU)
W
30
Prated(IDU+ODU)
W
1072 1072
Starting current
A
16.5
Circuit breaker rating
A
10
INDOOR
Fan type & quantity
Crossflow x 1
Fan speeds
H/M/L
RPM
1310/-/1100
Air flow
(1)
H/M/L
m3/hr
450/-/360
External static pressure
Min
Pa
0
Sound power level
(2)
H/M/L
dB(A)
53/-/49
Sound pressure level
(3)
H/M/L
dB(A)
41/-/35
Moisture removal
l/hr
0.9
Condenstate drain tube I.D
mm
16
Dimensions
WxHxD
mm
680x250x180
Net Weight
kg
6
Package dimensions
WxHxD
mm
740x310x248
Packaged weight
kg
8.5
Units per pallet
units
36
Stacking height
units
9 levels
OUTDOOR
Refrigerant control
Capillary tube
Compressor type,model
Rotary,Sanyo(Hua Run),C-1RV107
Fan type & quantity
Propeller(direct) x 1
Fan speeds
H
RPM
900
Air flow
H
m3/hr
1200
Sound power level
H
dB(A)
62
62
Sound pressure level
(3)
H
dB(A)
51
51
Dimensions
WxHxD
mm
610x520x240
Net Weight
kg
23.5
24
Package dimensions
WxHxD
mm
725x550x355
Packaged weight
kg
26
26.5
Units per pallet
Units
12
Stacking height
units
4 levels
Refrigerant type
R410A
Standard charge
kg(7.5m)
0.58kg
Additional charge
4m
≤
Length
≤
10m: +0g; 10m
≤
Length
≤
15m: +50g
Connections between units
Liquid line
In.(mm)
1/4”(6.35)
Suction line
In.(mm)
3/8”(9.53)
Max.tubing length
m.
Max.15
Max.height difference
m.
Max.7
Operation control type
Remote control
Heating elements
kW
Remote control(RC-5)
Others
(1)
Airflow in ducted units; at nominal external static pressure.
(2)
Sound power in ducted units is measured at air discharge.
(3)
Sound pressure level measured at 1-meter distance from unit.
(4)
Rating conditions in accordance to ISO 5151 and ISO 13253 (for ducted units).
(5)
Declaration torlenance is in accordance with EN14511.