2-6
PRODUCT DATA SHEET
SM ASP 1-E.2 GB
2.6
Alpha 12 SP ISR R410A / CSPI 12 R410A RC A1
Model Indoor Unit
ASP 12 R410A(ASP FLAT,ASP DF) FOR ISRAEL
Model Outdoor Unit
CSPI 12 R410A RC
Installation Method of Pipe
Flared
Characteristics
Units
Cooling
Heating
Capacity
(4)
Btu/hr
11600
12300
kW
3.40 3.60
Power input
(4)
kW
1.11
1.16
EER (Cooling) or COP(Heating)
tt
W/W
3.05 3.10
Energy efficiency class(SII)
F
F
Power supply
V
230
Ph
1
Hz
50
Rated current
A
5.0
5.3
Power factor
0.95
0.95
Prated (IDU)
W
30
Prated (IDU+ODU)
W
1405
Starting current
A
28
Circuit breaker rating
A
10
INDOOR
Fan type & quantity
Crossflow x 1
Fan speeds
H/M/L
RPM
1250/-/1000
Air flow
(1)
H/M/L
m3/hr
630/-/480
External static pressure
Min
Pa
0
Sound power level
(2)
H/M/L
dB(A)
55/-/50
Sound pressure level
(3)
H/M/L
dB(A)
41/-/36
Moisture removal
l/hr
1.1
Condenstate drain tube I.D
mm
16
Dimensions
WxHxD
mm
840x250x180
Net Weight
kg
7
Package dimensions
WxHxD
mm
900x310x248
Packaged weight
kg
9.5
Units per pallet
units
36
Stacking height
units
9 levels
OUTDOOR
Refrigerant control
Capillary tube
Compressor type,model
Rotary,Sanyo,C-RV133H1D
Fan type & quantity
Propeller(direct) x 1
Fan speeds
H
RPM
735
Air flow
H
m3/hr
1450
Sound power level
H
dB(A)
65
Sound pressure level
(3)
H
dB(A)
54
Dimensions
WxHxD
mm
760x545x245
Net Weight
kg
32.5
Package dimensions
WxHxD
mm
870x600x320
Packaged weight
kg
35
Units per pallet
Units
12
Stacking height
units
3 levels
Refrigerant type
R410A
Refrigerant chargless distance
kg(7.5m)
0.91kg
Additional charge
4m
≤
Length
≤
10m: +0g; 10m
Length
≤
15m: +50g
Connections between units
Liquid line
In.(mm)
1/4”(6.35)
Suction line
In.(mm)
3/8”(9.53)
Max.tubing length
m.
Max.15
Max.height difference
m.
Max.7
Operation control type
Remote control
Heating elements (Option)
kW
Others
(1)
Airflow in ducted units;at nominal external static pressure.
(2)
Sound power in ducted units is measured at air discharge.
(3)
Sound pressure level measured at 1-meter distance from unit.
(4)
Rating conditions in accordance to ISO 5151 and ISO 13253 (for ducted units).
CONTENT