background image

Central Heating Water Test Kit

Page 12

www.elector-water-treatment.com

EN

Kapitel 4 – Pflege, Kalibrierung und Anzeige des MP-7

1 General Information

1.1 General Information ............................................................................................................13

2 System Overview

2.1 Equipment..........................................................................................................................14
2.2 Overview Water-Quality Meter MP-7 ...................................................................................15
2.3 Technical Data of Water Quality Meter MP-7 ........................................................................16
2.4 Information about the Chemicals ........................................................................................16

3 Application Notes

3.1 Water Sampling ..................................................................................................................17
3.2 Testing the total hardness with the drop test........................................................................17
3.3 Testing the Electrical Conductivity with the Water-Quality Meter MP-7 ..................................18
3.4 Testing the pH-value with the Water-Quality Meter MP-7 ......................................................19

4 Maintenance, calibration and display of the MP-7

4.1 Storage of the pH Sensor ...................................................................................................20
4.2 Calibration of the pH Sensor ...............................................................................................21
4.3 Calibration of the Conductivity Sensor.................................................................................22
4.4 Battery replacement ...........................................................................................................23
4.5 Display Reading .................................................................................................................23

Contents

Summary of Contents for MP-7

Page 1: ...tilisateur Messkoffer zur Heizungswasseranalyse Central Heating Water Test Kit Mallette de mesure pour analyser l eau de chauffage DE EN FR Stand As from Valable partir de 07 2019 nderungen vorbehalte...

Page 2: ...den Chemikalien 5 3 Anwendungshinweise 3 1 Wasserprobenentnahme 6 3 2 Messen der Gesamth rte mit dem Tropfentest 6 3 3 Messen der elektrischen Leitf higkeit mit dem Kombimessger t MP 7 7 3 4 Messen d...

Page 3: ...indern fern Nutzen Sie die Materialien nur f r den ihnen zugedachten Anwendungszweck Personen und Sachsch den die durch Nichtbeachtung dieser Betriebanleitung entstehen sind durch das Produkthaftungsg...

Page 4: ...ssel und Schrauben f r Batterieabdeckung des Messger tes Leitf higkeitsmesselektrode pH Elektrolytl sung Messbecher Gesamth rte Tropfentest 2 Flaschen 1 Messk vette Beutel mit Kalibrierl sung f r elek...

Page 5: ...r gmbh de DE 2 2 bersicht Kombimessger t MP 7 Leitf higkeitsmesselektrode Messger t MP 7 Display Zwischenspeicher Betriebsmodus Ein Aus Kalibriertaste Batteriefachabdeckung Elektrodenschutzkappe Elekt...

Page 6: ...Chemikalien sind keine gef hrlichen Produkte pH Elektrolytl sung Kaliumchlorid 3 5 M L sung Leitf higkeitskalibrierl sung Kaliumchlorid 0 01 mol l 1 413 S cm pH Kalibrierl sung pH 7 00 Phosphat pH Ka...

Page 7: ...entnommen werden damit ber die Elektroden in das Wasser eingebrachte R ckst nde die nachfolgenden Messergebnisse nicht verf lschen 3 2 Messen der Gesamth rte mit dem Tropfentest Der Gesamth rtetest be...

Page 8: ...blesen Bitte beachten Sie dass die Temperaturkompensation nur im Bereich 0 50 C zuverl ssig funktioniert Schalten Sie das Ger t nach der Messung durch Dr cken der Taste aus Hinweis zur Wasserbeschaffe...

Page 9: ...n und her sodass vorhandene Luftblasen entfernt werden Warten Sie solange bis sich die Temperatur eingestellt hat Danach k nnen Sie den pH Wert ablesen Bitte beachten Sie dass die Temperaturkompensati...

Page 10: ...gen Sie die Elektrode mit einem sauberen Tuch Die pH Elektrode wird auf zwei Messwerte kalibriert Daher wird je ein Beutel mit Kalibrierl sung pH 7 00 und pH 10 00 ben tigt Legen Sie die Beutel bereit...

Page 11: ...lliert ist und berpr fen Sie dass die Symbole oder auf dem Display angezeigt werden 2 Tauchen Sie die Elektrode in die Kalibrierl sung 1 413 S cm bewegen Sie diese ein wenig und warten Sie bis sich de...

Page 12: ...Sie die alten Batterien und legen Sie vier neue vom Typ AAA UM 4 ein beachten Sie die Polarit t 3 Montieren Sie die Batteriefachabdeckung zur ck auf das Messger t Achtung 1 Stellen Sie die korrekte Po...

Page 13: ...he Chemicals 16 3 Application Notes 3 1 Water Sampling 17 3 2 Testing the total hardness with the drop test 17 3 3 Testing the Electrical Conductivity with the Water Quality Meter MP 7 18 3 4 Testing...

Page 14: ...rinse the area immediately with water Please consult your doctor in case of severe irritations Keep away from children Only use the instruments and the chemicals for their intended purpose The produc...

Page 15: ...Allen key and srews for battery cover Conductivity Sensor pH Electrolyte Solution Measuring Cup Total Hardness Drop Test 2 flasks 1 Beaker Sachet with calibration solution electrical conductivity 1 4...

Page 16: ...tor water treatment com EN 2 2 Overview Water Quality Meter MP 7 Conductivity Sensor Water Quality Meter MP 7 Display Cache Operation mode On Off Calibration Battery Cover Sensor Protection Cap Sensor...

Page 17: ...ntact with eyes mouth and nose Keep away from children The chemicals are non toxic pH Elektrolyte Potassium Chloride 3 5 M Solution Conductivity calibration solution Potassium Chloride 0 01 mol l 1 41...

Page 18: ...easurement of pH and electrical conductivity a new sample should be taken for each measurement procedure so that residues introduced into the water via the sensors do not affect the subsequent measure...

Page 19: ...hat the automatic temperature compensation only reliably works in a range of 0 50 C Switch the device off after usage by pressing the button Notes on Water Quality In natural waters the electrical con...

Page 20: ...are removed As soon as the temperature shows stable value you can read the pH value on the display Please note that the automatic temperature compensation only reliably works in a range of 0 50 C Swit...

Page 21: ...r with a clean soft cloth The sensor needs to be calibrated with two reference values Thus you need one sachet each pH 7 00 and pH 10 00 Calibration 1 Make sure that the pH sensor is installed and tha...

Page 22: ...and 1 413 S cm flashes As soon as the flashing stops the display shows SA and End The device returns to the measuring mode automatically Attention 1 If you need to measure a liquid with a high conduc...

Page 23: ...key 2 Replace the old batteries with for new of the type AAA UM 4 note the polarity 3 Reassemble the cover Attention 1 Make sure that the polarity of the batteris is correct 2 Don t remove the o seal...

Page 24: ...relatives aux produits chimiques 27 3 Consignes d utilisation 3 1 Pr l vement d eau 28 3 2 Mesure de la duret globale avec le test goutte goutte 28 3 3 Mesure de la conductivit lectrique avec l appar...

Page 25: ...pour l usage pr vu Les dommages personnels et mat riels cons cutifs au non respect de la pr sente notice d utilisation ne sont pas couverts par la loi allemande sur la responsabilit du producteur pou...

Page 26: ...pour le couvercle du compartiment piles de l appareil de mesure lectrode de mesure de la conductivit lectrolyte pH verre doseur test goutte goutte de la duret globale 2 flacons 1 r cipient de mesure s...

Page 27: ...le de l appareil de mesure combin MP 7 lectrode de mesure de la conductivit appareil de mesure MP 7 cran m moire tampon mode de fonctionnement touche marche arr t talonnage couvercle du compartiment p...

Page 28: ...roduits dangereux lectrolyte pH solution de chlorure de potassium 3 5 M Solution d talonnage de la conductivit chlorure de potassium 0 01 mol l 1 413 S cm Solution d talonnage du pH 7 00 phosphate Sol...

Page 29: ...afin que les r sidus introduits dans l eau par les lectrodes ne faussent pas les r sultats suivants 3 2 Mesure de la duret globale avec le test goutte goutte Le test de duret globale se compose de 2...

Page 30: ...uite lire la mesure en S cm Attention la compensation thermique ne fonctionne de mani re fiable que dans l intervalle 0 50 C Apr s la mesure arr ter l appareil en appuyant sur la touche Consignes rela...

Page 31: ...reil de mesure dans le verre doseur et agiter l lectrode pour supprimer les bulles d air existantes Attendre que la temp rature se soit stabilis e On peut ensuite lire la valeur pH Attention la compen...

Page 32: ...on humecteur et nettoyer l lectrode avec un chiffon propre L lectrode pH est talonn e au moyen de deux mesures Il faut donc utiliser respectivement un sachet de solution d talonnage pH 7 00 et un sach...

Page 33: ...la conductivit est install e et v rifier l affichage des symboles ou sur l cran 2 Plonger l lectrode dans la solution d talonnage 1 413 S cm agiter un peu et attendre que la valeur se stabilise Mainte...

Page 34: ...a cl six pans 2 Retirer les anciennes piles et remplacer par quatre neuves de type AAA UM 4 attention la polarit 3 Replacer le couvercle du compartiment piles sur l appareil de mesure Attention 1 S as...

Page 35: ......

Page 36: ...elector GmbH D sseldorfer Stra e 287 42327 Wuppertal Deutschland Telefon 49 0 2058 1790863 Telefax 49 0 2058 1790864 E Mail info elector gmbh de Internet www elector gmbh de...

Reviews: