background image

CAUTION

Do not pull, bend or place a heavy object on top of a cable. 

Otherwise, the cable may be damaged, and a fire or electric shock may occur.

The attached dedicated USB cable is for charging the main unit only. 
The dedicated USB cable cannot be used for communications or charging 
other devices.

Do not use a travel converter or other transformers to charge the product. 

It may cause heating and fire.

Do not charge the device using a vehicle's cigarette lighter. 

Otherwise, a fire, heating or electric shock may occur.

If you are charging it with a commercial charger using an AC power supply, read 
the charger's instruction manual thoroughly and follow the safety instructions.
When charging, insert the dedicated USB cable all the way. 

Otherwise, a fire or electric shock may occur.

Do not touch the special USB cable or gel pad with wet hands. 

Otherwise, an electric shock, malfunction or accident may occur.

Do not use a special USB cable when it is damaged, or when the USB 
connector insertion receptacle is loose. 

Otherwise, a fire or electric shock may occur.

Do not pour water or any other liquid into the main unit. Do not let the main 
unit get wet. 

Otherwise, heating, cracks or fire may occur.

Keep the device away from children. 

Otherwise, accidents may occur. If a child swallows the main unit, consult a 
specialist immediately.

If any failures occur, stop using it immediately and turn it off. Contact the 
distributor or our information center.

Follow local disposal requirements to dispose of the product.

Charge the product at least once every three months. 

The product may not be able to charge if it is fully discharged.

Attach the gel pad onto the skin securely. 

The main unit will automatically power off when the gel pad is removed from 
the skin. 
The gel pad cannot securely attach to body hair and doing so will age the gel pad.

8

No wet hands

Summary of Contents for Eclear LEANUP

Page 1: ...manuals in the country of purchase www elecom co jp global download list manual Thank you for purchasing Eclear leanup This Instruction Manual features operating methods as well as precautions for saf...

Page 2: ...press When unconnected to the main unit the pairing settings interface is displayed Due to continuous version upgrades specifications are subject to change without notice 2 This product is an EMS prod...

Page 3: ...less security 9 Package contents 10 Names of individual components 11 Preparation Charging 12 Attaching the gel pad 14 Use Basic operations 16 Using the dedicated app ECLEAR APP 18 Examples for applyi...

Page 4: ...e can be stimulated What is relaxation frequency The relaxation frequency is a low frequency in the range of 20 to 30 Hz By relaxing the muscles contracted by the deep layer frequency you can train fo...

Page 5: ...al equipment Internally implanted electronic devices such as pacemakers Electrical life support devices such as arti cial hearts and lungs Wearable medical electrical devices such as an ECG If used wi...

Page 6: ...ur doctor before using the product if any of the following conditions apply You are undergoing treatment or suffering a health condition Malignant cancer Heart or cranial nerve abnormalities Your temp...

Page 7: ...on the same day Do not use it for more than 30 minutes It may cause accidents or discomfort Ensure the main unit and gel pad are connected correctly and securely before use Do not use it on more than...

Page 8: ...pad with wet hands Otherwise an electric shock malfunction or accident may occur Do not use a special USB cable when it is damaged or when the USB connector insertion receptacle is loose Otherwise a...

Page 9: ...s that require a license specific low power radio stations that require no license and amateur radio stations WARNING Do not use this product on a machine that may have significant adverse effects due...

Page 10: ...ite Gray Core pad 1 consumable Accessories Sold Separately Inquire the retailer for details on separately sold accessories The following items are sold separately Accessory Instruction Manual 1 Storag...

Page 11: ...ctive film Gel Pad Main Unit Gel pad Dedicated USB Cable USB A port USB micro B connector When using the core pad 11 Front side Back side Power button switch mode button Convex Strong button USB port...

Page 12: ...C are continuously lit A B C and D are all continuously lit B blinks A is continuously lit C blinks A and B are continuously lit USB connector slot PC AC adapter for charging Dedicated USB cable USB m...

Page 13: ...at up or start a fire The product cannot be operated while charging Certain mobile power supplies may not be suitable for charging After repeated charging of the main unit the time a full charge lasts...

Page 14: ...rom the gel pad yet Make sure that the main unit is powered off LED indicator is off Connect the gel pad terminal to the main unit until you hear a click Connect the gel pad terminal to the main unit...

Page 15: ...top of metal such as a necklace or navel piercing Do not apply gel pads on tattoos CAUTION 15 Attaching the gel pad 3 Attach the gel pads to the desired body parts Attach the gel pad onto the skin sec...

Page 16: ...the mode changes A B C D A It makes a long beep sound when it returns to mode A 2 Adjusting the training level 3 You can choose the desired intensity from fifteen levels When connecting to the power s...

Page 17: ...t the same time two beeps will sound indicating that all sound has been muted For security reasons sound is generated for certain operations even in mute mode This is not a fault If you accidentally m...

Page 18: ...played Click Download Android version The Google Play download page is displayed 18 Please use the dedicated ECLEAR APP to activate and use the product Although this product can be used separately you...

Page 19: ...P On a smartphone with the dedicated ECLEAR APP installed pair the smartphone with the product using Bluetooth For details refer to the smartphone user manual Paring phone and product 1 Choose Setting...

Page 20: ...app ECLEAR APP Continued 20 Blinks in the sequence of A B C D A Power button Starting the dedicated ECLEAR APP 2 Pair the product with a smartphone 3 Tap the icon When the power button is pressed the...

Page 21: ...t power supply When the pairing settings page is displayed follow the prompts on the page to pair the product with the smartphone or laptop Follow the prompts on the page for the product to automatica...

Page 22: ...the gel pad is removed from the skin or the main unit the power turns off automatically To disconnect the product during a workout via the app use the button s on the product To change the connected...

Page 23: ...thigh calf CAUTION Do not use it on more than two locations at the same time Half of the thickness when you pinch the arm with your elbow bent at 90 degrees Half of the thickness when you pinch your a...

Page 24: ...ectly on to your skin Examples for applying gel pads Continued 24 Rectus abdominis core pad Abdominal oblique twin pad Adductor muscles twin pad Quadriceps femoris core pad Tibialis anterior twin pad...

Page 25: ...use 25 Triceps brachii twin pad Latissimus dorsi core pad Gluteus maximus core pad Biceps femoris core pad Triceps surae twin pad Gluteus medius core pad Core pad Twin pad Back...

Page 26: ...d off before peeling the gel pad from your skin Do not touch the adhesive surface of the gel pad Instead hold onto the knob to peel it off Do not disconnect the gel pad from the main unit Attach it to...

Page 27: ...aintenance replace the gel pad Main unit maintenance Wipe dirt off the main unit with a soft cloth CAUTION Do not let water get into the main unit or USB port After use 27 Run a small amount of water...

Page 28: ...ons Storage temperature 10 C to 60 C Storage humidity 20 85 RH Maintenance and storage precautions Do not use benzene or thinner to service the product Do not store the product in the locations descri...

Page 29: ...st that you recycle them Lithium ion batteries are precious resources that can be recycled so we request that you recycle them Precautions for disposing of lithium ion batteries Do not disassemble the...

Page 30: ...pply Short press the button during use P 16 The main unit and gel pad are not connected correctly Disconnect the power and then reconnect the main unit and gel pad P 14 Power disconnected during use B...

Page 31: ...veral seconds P 27 The gel pad is not properly connected Connect it correctly by pushing it in until it clicks P 14 The adhesive surface of the gel pad is dirty or damaged Gel pads are consumables Whe...

Page 32: ...hone P 9 The product cannot be operated via a smartphone Before pairing press the button on the product Before pairing press the button on the product to start a workout without pairing In this case y...

Page 33: ...1 Charge time Approx 2 5 hours 3 Operating time Over 90 minutes fully charged 4 Rated output voltage Approx 42 V Deep layer frequency Approx 2000 5000 Hz Relaxation frequency Approx 20 30 Hz Timer Ap...

Page 34: ...rk Google Google trademark Google Play Google Play trademark Google LLC trademark or registered trademark Apple Apple trademark iPad iPhone are trademarks of Apple Inc registered in the U S and other...

Reviews: