GDU
27-1500
Original Instructions
8
9901X0265 Issue 2
1.5.3 Physical Specification
Specifications
Details
Dimensions (W x D x H)
365 x 320 x 160mm (14.4" x 12.62 x 6.3")
Weight
6.4kg (14.3lb)
Enclosure
Aluminium die-cast, powder coated
Display
None
Protections Class
I, IP20
Pollution degree/installation
category
2; II
Power requirements
110-115/10%, 50/60Hz, 115VA, single
phase
Operating Environment
Temperature: 0 to 40
o
C(32 to 104
o
F)
Humidity: 10 to 90%, non-condensing
Altitude: to 2000m (6590ft)
Storage Environment
Temperature: -40 to 70
o
C(-40 to 158
o
F)
Humidity: 10 to 90%, non-condensing
Memory
4Mb
Connections
RS232, Ethernet, DIN
Fuses
2.5A, T, 250VAC
1.5.4 Replacement Parts
WARNING
Personal injury hazard. Use of non-approved parts may cause personal injury,
damage to the instrument or equipment malfunction. The replacement parts in
this section are approved by the manufacturer.
AVERTISSEMENT
Risque de blessures corporelles. L'utilisation de pièces non approuvées
comporte un risque de blessure, d'endommagement de l'appareil ou de panne
d'équipement. Les pièces de rechange de cette section sont approuvées par le
fabricant.
The user replaceable parts include the AC inlet fuses, analogue input modules,
detachable power cord and CPU module.
See Maintenance section for details on fuse replacement.
Replacement/additional Analogue Input modules have the part number 1914B0046 or
27-1505.
Replacement CPU modules have the part number 1914B0065.
Replacement North American detachable power cord part number 8608-0012 (US
office) or 6099X0229 (UK office).