5
800.925.1491
|
G E N E R A L I N F O R M A T I O N
P R O D U C T U S A G E
The Sherwood Fireplace is designed to burn solid woods or gas outdoors. This unit is not designed to sit directly against combustible
materials. This unit is not designed to be built into a wood structure. The Sherwood Fireplace is designed as an outdoor unit only.
As required due to heat and weight, this unit must be built on a non-combustible concrete slab (code-compliant frost-free footer)
designed to carry the total weight of the entire fireplace and chimney structure along with finished veneer. Approximate weight of
installed unit is 4175 lbs. (excluding stone veneer finish).
Use solid wood, plumbed propane or natural gas fuel only.
BTU gas set used with this product must be approved for outdoor use.
M O D I F I C A T I O N O F F I R E P L A C E
Modifications to the Sherwood Fireplace are prohibited. Any modifications may void claims, listings and approvals and could result in an
unsafe and potentially dangerous installation.
The installer indemnifies the manufacturer of all claims and under no circumstances will manufacturer be liable for consequential,
incidental, indirect, punitive or other damages of any kind or nature, whether foreseeable or not, based on any claim by any party as to
the modifications of the fireplaces.
M A N T E L C L E A R A N C E S
A decorative mantel may be installed above the firebox opening of the Sherwood Fireplace
provided the front edge of the mantle extends no more than 10" from the face of the fireplace
and is a minimum of 12" above the opening
(Figure A)
.
V E N T I L A T I O N
The Sherwood Fireplace is designed as an outdoor unit only. No additional ventilation or
circulation is required.
C O M B U S T I B L E C L E A R A N C E S
The distances to combustibles while burning solid wood shall be no less than 60" from the front
of firebox, 12" from the side walls and 4" from the back wall. When a vented or ventless gas log
set is used and the top of the chimney capped, the clearances shall be no less than 16" from
the front, 4" from the back and 1" from the top of the chimney.
D A M A G E D P A R T S
If unit is delivered with obvious damage due to freight, please notify driver or refuse delivery. If product is damaged on job site, you may
be able to repair unit using adhesive and/or mortar. If damage is severe, contact your dealer to arrange shipment of replacement parts.
M A I N T E N A N C E
Please contact a professional chimney sweep at least once each year to inspect and make recommendations regarding the maintenance
of your outdoor fireplace. In the event you have added a decorative chimney termination or rain cap to your fireplace, please be prepared
to inform the chimney sweep as to the best method to perform proper inspection/maintenance.
Figure A
10"
12"
Firebox
Mantel
Fireplace
Profile