FAULT MESSAGE DISPLAY
Tare (set zero) Function
It is easy and convenient to build up & mix different ingredients together all in the same cup. After
the first ingredient is added and measured, you may add another ingredient after performing the
tare function below.
- place the cup with first ingredient on a flat table
- single press [0] button. The reading will reset to zero and the “TARE” icon will remain
on the upper display.
Now you can add your additional ingredient. Only the weight or volume of the last ingredient
added in measured. Continue above procedure to build up different ingredients for your recipe.
Reversing the Tare Function
Right after the tare function has been performed and the display is showing “0” reading with the
“TARE” icon appeared, you can press [0] button to resume the original weight or volume reading
just before the tare function and the “TARE” icon will disappear.
The reverse tare function and reversing the tare function only operate when the cup is placed on
a flat surface.
Hold [0] button for 3 seconds to turn off the unit.
The unit turns off automatically after 5 minutes in idle state.
IMPORTANT NOTE:
- It is easy and convenient to mix different ingredients in the cup. However when mixing your
ingredients, you should avoid pressing down the bottom of the base where the sensitive weight
scale components are located. Excessive force applied to the base of the cup may permanently
damage the scale inside and provide inaccurate reading.
- The transparent cup can withstand up to maximum 70
O
C of food or liquid
NOTE: The volume measurement is converted from the weight & the pre-set density of the
ingredient by the processor in the cup. There are different types of milk, oil, sugar or flour in the
market. Different types, brands & origins of the same ingredient have different density. For this
reason, some variation on the volume measurement will occur depending on the type of
ingredients you are using. The volume reading provided by the cup can only be used as an
approximate value.
The density and type of ingredients being used in the cup are shown below.
Unstable (UnST)
The scale is unstable and the unit will turn off automatically.
Place the cup on a flat table and turn on the unit again
by pressing [0] button once.
Error (Err)
The scale is overloaded. The weight or volume in the cup exceeds
the maximum display range.
FOT. 2
Product
Density
Units selection available
Water
1 kg/L
mL, CUPS, FL OZ
Milk
1.03 kg/L
mL, CUPS, FL OZ
Oil
0.9 kg/L
mL, CUPS, FL OZ
Granulated sugar
0.84 kg/L
GRAMY, CUPS, LBS OZ
Flour
0.6 kg/L
GRAMY, CUPS, LBS OZ