I
n this mode you can preset an interval of time during which to allow water heating. To do this you can preset the two
timers using the menu
Set On / Off Time.
When switching into this mode, the water heater shall turn on only if the
current time is within the range of one of the scheduled periods and the water temperature is below the temperature
set. You can use this mode for example if you use hot water only in the morning and the evening, and the entire
quantity of hot water ends in the morning. Then you can set a timer in a time interval during the night, and the other -
before you need water during the day. The interval, which will enable the water heater must be consistent with the
water tank ability to reach the temperature set for the period. You can find the information about the time needed for
water heating by your water heater in the device technical description.
1
.4.
Delayed Start
mode
The temperature set for heating or the
temperature measured when the water heater
is operating
Hour and date of water heater future switch on
Set - Temperature set
When you are away from home for a long period and want when you get back to have immediately hot water, you
can use the
Delayed Start
mode to switch on the device, however you must preset the time for switching on in the
menu
Next Start
and it must be after the current date and time. When it reaches the preset time for Delayed Start,
the device shall activate the
Heating mode.
1.5. Water heater switch off
By pressing subsequently the
F
button you will eventually switch off the water heater. In this status the screen looks
like Display I and the water heater is off.
Even in the off status the function
Anti-freeze
that protects the water tank from temperatures falling at
dangerously low levels is automatically saved. Therefore, when there is a danger of a drop in ambient
temperature, it is recommended that the water tank should not be disconnected from the mains!
2
.
Temperature setting
When the tank is in a switch on stratus and is in not in mode
Smart Control
, by pressing one of
the buttons ▲ or ▼ you can access the mode
Change Temperature Set
. The digit in the
Water Temperature flashes and the temperature set appears. Above it is marked
Temp
. With
the following keystrokes you may change the assignment in the desired direction. The altered
temperature is remembered by pressing
Г
or after 5 seconds without pressing a button. If any of the buttons ▲ or
▼ remains above 0.8 seconds, the value of the temperature set starts automatically to increase or decrease. The
temperature limits are set between 20°С and 75°С.
3. Access to „Settings“ mode
In order to access the
Settings
mode the water heater must be switched on (Display II). Press the
F
button for more
than 1.5 seconds and you shall have subsequent access to all settings menus. The general principles to observe
for all settings are the following:
џ
T
he value to edit is the flashing one;
џ
Button
Г
serves for access to the display field to edit;
џ
To increase or decrease the blinking field values press buttons ▲ and ▼. If one of these buttons is kept for
more than 0.8 sec. the value set shall start automatically to increase or decrease. In this case, the edited field
does not flashes, just changes its value.
џ
Pressing the
F
button exits the current setup screen. If there are changes made in any of the screen
parameters these are stored and the unit exits the settings mode. If no changes are made in the current
screen pressing the
F
button commands the unit to proceed to the next screen settings, if any.
џ
W
hen the clock readings are flashing, it means that it has not been collated. In this case it is possible to enter
the setup mode for time and date even if the water heater is in switched off mode (Display I).
S
ettings:
џ
Next start
– enter the time and date to switch on water heating when operating mode
Delayed Start
is activated.
EN
15