USER MANUAL  EWD1  V1.0                                     

5

Here “ID1” means magnetic door contact identification number. This identification number can be found on the back of the device. 

The system automatically provides two security zones to the connected door contact. The system informs about this via SMS messa-

ge, for example, “ID1:Z14:ID1Z15” - here instead of “ID1” will be identification number of the module that you want to connect, “Z14 

and Z15” – the numbers of free zones provided by the system.
You can bind more than one magnetic door contact at a time. In such a case separate identification numbers by “;” symbol, for exam-

ple: “ XXXX SET:ID1;ID2; ... ;ID16 ”.

4.2. Settings of Activated Zones

After activating magnetic door contacts EWD1 each of them is automatically given zones numbers and set to the default settings.

4.2.1. Adjusting Alarm Text

Alarm text of a particular zone is adjusted by sending the following SMS message:

 
Here instead of “Text” enter the required alarm text consisting of up to 24 characters and instead of “Z2” 

indicate the number of the corresponding zone. You receive this alarm text by SMS message when a 

corresponding zone is triggered. To change alarm text of more than one zone separate entries by “;” 

symbol, for example: “XXXX Z2:Text2;Z3:Text3”.

4.2.2. Enabling/Disabling Zones

You can choose which zones, after activating the alarm in the whole system, will be enabled or disabled. 

By initial factory default parameters all activated zones are enabled.
Any zone can be enabled by sending SMS message with the following format*:

 
Any secured zone can be disabled by sending SMS message with the following format*:

* Indicate as many zones as you want to change their statuses separating entries by “;” symbol, as shown in the examples provided.

4.3. Requesting system status information

To find out the alarm texts and statuses of activated zones, send the following SMS message:

 
You will receive system response via SMS message, for example: “Z1:ON/OFF:Zone1; Z2:ON/OFF:Zone2; 

C1:ON/OFF:Controller1; C2:ON/OFF:Controller2“
This information SMS message indicates all wireless ELDES devices connected to the system and their 

current parameters.

ATTENTION:

 System informs about all active zones. If there are many active zones, the system informs about all of them in several 

SMS messages.

4.4. Requesting number of available slots to connect wireless devices

To find out the number of available slots to connect wireless devices to the central device of security system send the following SMS 

message:

NOTE: 

maximum number of wireless devices that can be connected to the central device of the security system station is 16 units.

EWD1

EWD1

EWD1

1111 Z5: 

Doors  

opened

1111 Z2: 

ON

1111 STA 

TUS

XXXX_Z2:TEXT

XXXX_Z1:ON;Z2:ON;Z3:ON

XXXX_STATUS

XXXX_STATUS_FREE

 XXXX_Z1:OFF;Z2:OFF;Z3:OFF

Summary of Contents for EWD1

Page 1: ...MAGNETIC DOOR CONTACT EWD1 ...

Page 2: ...nce for wireless connection is 150 meters in open areas 1 Device Installation 1 Open EWD1 case and insert the battery 2 Magnetic door contact consists of two parts a magnet and a sensor Sensor components are a mounting part and the sensor Magnet components are a mounting part and the cover 2 1 Fix the sensor mounting part with two screws on the door or window jamb 2 2 Fix the magnet mounting part ...

Page 3: ...eration time 18 months Radio transmitter receiver frequency 868 Mhz Range of Operating Temperatures 20 55ºC Door contact dimensions 60x37x18mm Magnet dimensions 60x17x16mm Radio communication range 30 meters in premises 150 meters in open areas Compatible with security systems ELDES Wireless This operation time might vary in difference conditions Changing the battery Only CR2032 3V Lithium batteri...

Page 4: ...ystem settings Software ELDES Configuration Tool is a freeware and can be downloaded from website www eldes lt 4 Configuration command SMS Messages ATTENTION send command SMS messages to the number used by the central device of the security system All SMS messages should start with the main 4 digit user password in the examples provided XXXX marking is used Underscore symbol _ is used to represent...

Page 5: ...se which zones after activating the alarm in the whole system will be enabled or disabled By initial factory default parameters all activated zones are enabled Any zone can be enabled by sending SMS message with the following format Any secured zone can be disabled by sending SMS message with the following format Indicate as many zones as you want to change their statuses separating entries by sym...

Page 6: ...king The new magnetic door contact is provided with the same zone number with all previous settings valid for the old one 4 6 Deleting magnetic door contact EWD1 To delete magnetic door contact EWD1 from the security system send the following SMS message Here instead of ID indicate identification number ID of the magnetic door contact EWD1 want to dele te Removed from the system zones can be used ...

Page 7: ...t use the system where it can be interfere with other devices and cause any potential danger Don t use the system with medical devices Don t use the system in hazardous environment Don t expose the system to high humidity chemical environment or mechanical impacts Don t attempt to personally repair the system Any system repairs must be done only by qualified safety aware personnel Copyright ELDES ...

Reviews: