MAGNETIC DOOR CONTACT 

 

EWD1

Summary of Contents for EWD1

Page 1: ...MAGNETIC DOOR CONTACT EWD1 ...

Page 2: ...nce for wireless connection is 150 meters in open areas 1 Device Installation 1 Open EWD1 case and insert the battery 2 Magnetic door contact consists of two parts a magnet and a sensor Sensor components are a mounting part and the sensor Magnet components are a mounting part and the cover 2 1 Fix the sensor mounting part with two screws on the door or window jamb 2 2 Fix the magnet mounting part ...

Page 3: ...eration time 18 months Radio transmitter receiver frequency 868 Mhz Range of Operating Temperatures 20 55ºC Door contact dimensions 60x37x18mm Magnet dimensions 60x17x16mm Radio communication range 30 meters in premises 150 meters in open areas Compatible with security systems ELDES Wireless This operation time might vary in difference conditions Changing the battery Only CR2032 3V Lithium batteri...

Page 4: ...ystem settings Software ELDES Configuration Tool is a freeware and can be downloaded from website www eldes lt 4 Configuration command SMS Messages ATTENTION send command SMS messages to the number used by the central device of the security system All SMS messages should start with the main 4 digit user password in the examples provided XXXX marking is used Underscore symbol _ is used to represent...

Page 5: ...se which zones after activating the alarm in the whole system will be enabled or disabled By initial factory default parameters all activated zones are enabled Any zone can be enabled by sending SMS message with the following format Any secured zone can be disabled by sending SMS message with the following format Indicate as many zones as you want to change their statuses separating entries by sym...

Page 6: ...king The new magnetic door contact is provided with the same zone number with all previous settings valid for the old one 4 6 Deleting magnetic door contact EWD1 To delete magnetic door contact EWD1 from the security system send the following SMS message Here instead of ID indicate identification number ID of the magnetic door contact EWD1 want to dele te Removed from the system zones can be used ...

Page 7: ...t use the system where it can be interfere with other devices and cause any potential danger Don t use the system with medical devices Don t use the system in hazardous environment Don t expose the system to high humidity chemical environment or mechanical impacts Don t attempt to personally repair the system Any system repairs must be done only by qualified safety aware personnel Copyright ELDES ...