Safety instructions
Please read and follow these safety guidelines and assembly instructions in order to maintain safety of operators and people around:
•
GSM switch - gate controller Esim110 (further referenced as the system) contains an GSM Switch - Gate controller in GSM
850/900/1800/1900 MHz bands.
•
Don’t use the system where it can interfere with other devices and cause any potential danger.
•
Don’t mount the system next to medical equipment or devices, if they require so.
•
Don’t use the system in hazardous environment.
•
Don’t expose the system to high humidity, chemical environment or mechanical impacts.
•
Don’t attempt to personally repair the system.
•
System label is on the bottom side of the device.
System Esim110 is a device mounted in limited access areas. Any system repairs must be done only by qualifi ed, safety aware
personnel.
Mains power must be disconnected before any installation or tuning work starts. The system installation or maintenance
must not be done during stormy conditions.
The system must be powered by main 10-24V 50Hz ~200mA AC or 10-24V
200mA DC power supply which must be
approved by LST EN 60950-1 standard and be easily accessible.
Any additional devices linked to the system Esim110 (computer, sensors, relays etc.) must be approved by LST EN 60950-1
standard.
External power supply can be connected to AC mains only inside instal-
lation room with automatic 2-pole circuit breaker capable of disconnec-
ting circuit in the event of short circuit or over-current condition. Open
circuit breaker must have a gap between connections of more than 3mm.
Fuse F1 type C1S 2.5A. Blown fuse cannot be replaced by the user and the replacement fuses have to be exactly the same as
indicated by the manufacturer.
The device is fully turned off by disconnecting 2-pole switch off device of the external power supply or any other linked
device that the system Esim110 is powered from.
The WEEE (Waste Electrical and Electronic Equipment) marking on this product or its documentation indicates that in the EU the
product must not be disposed of together with household waste.
Phase
AC 230V
50 Hz/DC 24V
USB cable
Null
ESIM110
PE
If you use I security class computer for setting the parameters it must be connected to earth.
ESIM110 can be powered direct from 12V battery. The battery capacity shouldn‘t be higher than 7Ah.