Connector functionality
Labeling
Explanation
DC+
DC+ power in connector
COM
Earth pin
OUT
Controlled output (Open collector)
Z1
Digital input Z1
Z2
Digital input Z2
LED indicator status
Meaning
OFF
No network connection
Every 1 sec
Not synchronized with network
Every 2 sec
Synchronized with network
1.5 Connection Circuit
System ESIM021 and security unit COM must be connected.
ESIM021 can be powered from battery. The battery capacity shouldn‘t be higher than 7Ah.
Inputs Z1 and Z2 are connected to security unit PGM outputs if PGM are implemented as open
collector circuit or any other circuit and if it commutates with COM.
It is also possible to connect Z1 and Z2 inputs to, for instance, motion sensor or any other sen
-
sor as well as automatics device provided the inputs are commutated with COM.
1.6 System installation
The system box should be fixed with four screws to the wall. Since the ESIM021 has integrated GSM antenna, it should not be
installed into the metal box. For the connection of power supply, output and inputs connectors should be used 1 thread 0,5mm2
cable. Cables should be connected to the connectors and brought through the special cover hole for cables.
1.
Enter one or two numbers into SIM card under names “User1” and “User2”.
2.
Place SIM card in the holder but make sure that SIM card PIN code request is disabled (PIN code can be disabled by putting SIM
card into mobile phone and following proper menus). SIM card should not have any remaining SMS messages. All SMS text
messages from SIM card will be automatically deleted during system start.
3.
Connect the circuit as shown in Fig. No.2. Power supply cables are connected last. When connecting ESIM021 to security cen-
tral system power supply, usually the security system AUX output is used. Security system power supply must be disconnected
before connecting ESIM021. The system should not be installed on metal surfaces.
4.
When DC power supply is used, there is no need to connect any other power supplies.
5.
The system will start in less than a minute.
GSM communication and
control system ESIM021
Alarm system or other appliance
P
G
M
1
P
G
M
2
+12V
Z1
Z2
DC COM OUT