14
1. General Information
1.1 Function
ESIM010 is a microcontroller based device used to control gate automatics, road barriers or to remotely turn on the electronic
device over GSM network.
Examples of using the system:
• Controlling road barriers in the yards of blocks of flats or offices
• Opening personal house gates
• Turning on an electronic device for a specified period.
E. g., aquarium lighting, turning on the pump, watering, controlling heating in premises etc.
• Turning on the system
• Turning on any electric device controlled with using ON/OFF function
• Rebooting “frozen” system, e. g., computer network or server.
• Notification about a fault in gate or other automatics device.
1.2 Operation Description
Automatic gate controller system ESIM010 works over GSM network. Gates are opened or any other electronic appliance is turned
on by a free phone call. The phone is automatically rejected.
On calling to the phone number of the system it checks whether the caller is recorded in the database. If he/she is saved in the sys-
tem, the relay is turned on for a specified period. The system will ignore requests incoming from an unknown telephone number
or an SMS message with a wrong password.
Connecting open gates sensor or switch allows administrators receiving SMS message about the gates that did not close during
the preset period, for instance, if the gates or road barrier did not close during the particular time period.
1.3 Technical Specifications
Electrical, mechanical and other specifications
Supply voltage
10-24V ~ 200mA max or 10-24V DC
200mA max
Current used in standby model
not more than 50mA
GSM modem frequency
900/1800 Mhz
Number of outputs
1
Output type
NO (relay)
Number of “low” level (negative) inputs
2
Number of “high” level (positive) inputs
1
Allowable “low” level (negative) input voltage values
0-1.6V
Allowable “high” level (positive) input voltage values
5-50V
C1 output maximum commutating values
1A/24V DC; 0,5A/125V AC
Dimensions
70x85x57mm
Operating temperature range
-20…+55
o
C (-30...+55
o
C with limitations)
Number of administrators
5
Number of users
500