E
F
H
G
43 mm
10 mm
Ø
Model
RTS26E5001-01
Technical Details
Frequency:
868.30 MHz
Radiated power:
0.34 mW
Modulation:
FSK
Coding:
Easywave
Power supply:
1x 3-V-battery, CR2032
Operating temperature: -20 °C up to +60 °C
Range:
free-field: approx. 150 m
buildings: approx. 30 m
Dimensions (w/l/h):
33/166/8 mm
Weight:
34.0 g (incl. battery)
Scope of Delivery
Window handle contact RTS26 ALARM,
magnetic disc, battery holder, battery CR2032,
operating instruction
Intended Use
Only use the window handle contact RTS26
ALARM to transmit radio signals to the Radio
Alarm Annunciator RTRP02.
The manufacturer shall not be liable for any da-
mage caused by improper or non-intended use.
Safety Advice
Before using the device, carefully read
through the operating instructions!
Also note the operating instructions of the
receiver(s)!
Please check regularly the ready-to-transmit-
state of the device!
Have faulty devices checked by the manufactu-
rer!
Do not make any unauthorized alterations or
modifications to the device-!
Keep the batteries out of the reach of children!
RTS26 Radio Window Handle Contact ALARM
GB
Funktion
The window handle contact RTS26 ALARM is a
magnetic contact that signals the open/closed
status of a window acoustically and transmits an
alarm telegram wireless to the radio alarm annun-
ciator RTRP02.
If a window is opened while the window handle
contact is activated, a warning signal sounds for
approx. 1.5 minutes. You can deactivate this by
pressing the button for some time. Once the win-
dow is closed, the window handle contact activa-
tes itself automatically after 10 seconds.
The window handle contact is suited for standard
window handles with a rod dimension of 7 mm,
screw dimension of 10 mm and a hole spacing
of 43 mm.
Start-Up
1. Insert the enclosed battery into the battery
holder and put these into the RTS26.
Use only batteries of type CR2032. Make
sure the polarity is correct.
The positive pole
has to be visible!
(fig. 1)
2. Unscrew the window handle while the window
is closed. Remove the protective foil from the
rear adhesive pad of the window handle con-
tact and stick this onto the window frame.
Observe the correct position (the drill holes
must be vertically aligned). (fig. 2)
3. Insert the magnetic disc in the window handle
contact.
The magnet must point to the reed
contact.
(fig. 2)
4. Move the window handle through the magne-
tic disc back into the window and screw the
handle on again. (fig. 2)
5. With the windows closed, press the button
until the LED briefly blinks red. Now the win-
dow handle contact is activated. (fig. 1)
6. Memorize the transmission code in to the
RTRP02. Please read the operating inst-
ructions supplied with the alarm annuciator.
Open the window briefly, the Easywave code
A is transmitted to the alarm annuciator, the
LED on RTS26 illuminated in red and the
transmission code has been learned.
Handle Contact Activate / Deactivate
Press sequentially the button to activate or deac-
tivate the window handle contact.
D
B
A
C
Deactivated
Activated
RED
GREEN
Press the button,
the LED light up
red.
Press the button,
the LED light up
green.
fig. 1
fig. 2
A
Battery holder with
battery CR2032
B
Magnetic disc
C
Button and LED green/red
D
Alarm annuciator RTRP02
E
Magnet
F
Reed contact
G
Square bar max. 7 mm
H
Protective film from the
adhesive pad