Electrical connection
Dismantling
- Disconnect the system from voltage and
secure it against being switched on again.
- Use a screwdriver to carefully loosen the side
locking hook and pull the device forward to
remove it.
230V
230V
Ø
6 mm
60 mm
230V
Click!
Click!
A
Zeit (min)
Helligkeit (lux)
P
START UP
fig. 3
230 V AC
Installation
(see figure 3)
Disconnect the system from voltage and
secure it against being switched on again.
Drill the fixing holes (Ø 6 mm) into the wall
following the drilling template.
Remove the back of the motion detector (see
“Disassembly”) and pierce the membrane for
the cable throughput.
With no power running through them, run the
connection cables for the motion detector
and external button, if necessary through the
seals. Securely screw the back of the motion
detector to the wall.
Connect the connecting cables according to
the wiring diagram (see figure 2).
Place the motion detector on the base and
click it into place.
Set the Easywave receiver to learning mode
for the ON/OFF operating type, 2-button ope-
ration (see receiver operating instructions).
The receiver remains in learning mode for a
few seconds.
Switch the power supply for the motion detec-
tor back on while the receiver is still in learning
mode. The SM01 sends Easywave transmis-
sion code
A
and is now taught-in to the recei-
ver.
Conduct a walking test (see “Adjusting the de-
tection zone”) and set your preferred time and
brightness settings (see “Settings”).
Do not start the walking test until the moti-
on detector has switched off!
Please note that after the power supply
has been switched on, the motion de-
tector remains switched on for at least
40 seconds, or for the time set on the
motion detector.
push button
(optional)
ON
fig. 2
OFF
OFF
Time (min)
Brightness (lux)