background image

GB

Power Plug Radio Call Detector  RCP09

Models

Scope of Delivery

Safety Advice

Concept  of  Operations

The device may only be operated indoors as 
acoustic signaller for notifications of alarm 
signals and indicates the battery condition of 
the tranmitters (evaluation undervoltage 
telegram).

The outlet can only be used for mains voltage 
consumers.

The manufacturer will not be liable for damage 
caused by improper or inappropriate use

.

 

Intended Use

Function

Function/Chapter

Operation   

                    

[press the button]

LED-view RCP09

Further actions

Teaching in the 
call transmitter

1. button R   (>1,6 s)

2.

 call transmitter

button

button 

button 

flashes

button 

light up 

4 s

after 20 s operation mode

 

teaching in furthertransmitter

 

cancel

Teaching in 

acknowledgement 

transmitter

1.

Q   (>1,6 s)

2.

acknowl. transmitter

Q

button 

button 

button 

button 

flashes

button 

light up 

4 s

after 20 s operation mode

 teaching in furthertransmitter

cancel

 

Selecting the 
melody

button 
button 
button 

R
R
R

1. Westminster
2. March
3. Ringing Bell

default settings

Setting the 
volume/ 
flashlight

button 
button 
button 
button 
button 

Q
Q
Q
Q
Q

1. 
2. 
3. 
4. Quiet
5. Loud

Quiet and flashing light
Loud and flashing light
Muted 

(only flashing light)

default settings

Acknowledging 
a call

button 

button 

 acknowl. transmitter

R, 

Q or

Deleting 
individual 
transmitters

1. 

R

 + 

(>1,6 s)

2. call- or acknowledgement  

transmitter

R or 

Q

button 

button 

button 

button 

button 

flash

button R and Q light up 

R and Q 

 

4 s

after 20 s operation mode

cancel

deleting further 
transmitters

Reset to Default 
Settings 
(RESET)

1. 

R

 + 

Q (>1,6 s)

2. 

R

 + 

Q (>1,6 s)

button R or button Q

button 

button 

button 

button 

button R and Q flash

button R and Q light up 4 s

after 20 s operation mode 

cancel

default settings

Wall outlet

Loudspeaker

Button Q

Button R

Flashlight

RCP09 5001-12

868.30 MHz

GB

RCP09 5001-14

868.30 MHz

F/B

E
E

Power plug call signaller RCP09, operating 
instruction

Please  read  these  instructions 

carefully before using the device!

We  do  not  accept  any  liability  for  personal 
injury  or  damage  to  property  caused  by 
incorrect handling or non-observance of the 
safety instructions!

Observe  the  valid  laws  and  regulations  as 

well as the manufacturer's instructions for the 
devices to be operated!

Frequency:

868.30 MHz

Modulation:

FSK

:

230 V AC / 50 Hz

Current consumtion: max. 7 mA
Power consumption: approx. 0.3 W (stand by

: IP 20

:

-20°C to +35°C

:

60%

:

122 x 50 x 75 mm

:

190 g

Operating voltage

Loudness:

Distance 30 cm: 
quiet: 75 dB, loud: 82 dB

Degree

 of 

protection

Operating 
temperature
Max. relative air 
humidity
Mains output

Power plug 

(non switchable)

Max. contact load:
GB

13 A / 230 V AC

F/B (PL) 

16 A / 230 V AC

Dimensions 

(HxWxD):

Weight

Technical Details

Attention!

Observe  the  admissible  supply 

voltage and the maximum contact load of the 
wall outlet (

see „Technical Details“

)!

Do not plug one Call Detector  into another. 

The Call Detector  is only de-energized when 

it is disconnected from the mains supply.

The Call Detector  must be easily accessible.

Have malfunctioning devices checked by the 

manufacturers!

Do not open the appliance's casing!

 

Do not make any unauthorized alterations or 

modifications to the unit!

The call signaller RCP09 serves for acoustic and 
optic  signalling  of  care  requests.  The  call  is 
triggered by a handheld radio transmitter.

Þ

ringing tone

Þ

The outlet of the call signaller can be used as an 
outlet for any electric devices.

The melodies "Westminster", "March" or "Ring 
tone" can be selected. By default, the call 
signaller plays the "Westminster" melody.

Cyclic call signalling:

1.    1.5 min   ringing tone

3 min break, 

2.    1.5 min   

3 min break, 

3.    1.5 min   

10 min break,

4.    1.5 min   

timeout.

The  optic  signal  by  the  flashlight  (if  activated) 
continues until the call is acknowledged. The call 
can  be  acknowledged  directly  on  the  call 
signaller or with an acknowledgement transmit-
ter.

It  is  also  possible  to  evaluate  an  undervoltage 
telegram  indicating  a  low  battery  status  of  the 
radio transmitters RT26, RT27 and RT28. 

The  weak  battery  status  is  indicated  by  the 
alternate  blinking  of  the  buttons  and  can  be 
deactivated by pressing one of the two buttons.

ringing tone

Þ

ringing tone

Þ

Altogether 64 send codes can be programmed in 
the  call  signaller  (32  request  codes  and  32 
acknowledgement codes). 

Start-up

1. Plug  the  call  detector  into  a 

properly  functioning  earthed 
outlet.  You  will  hear  a  brief 
acknowledgement signal.

2. Teach  the  coding  of  the  call  transmitter  into 

the call detector (see section "Teaching in the 
call transmitter").

3. Teach  the  coding  of  the  acknowledgement 

transmitter into the call detector (see section 
"Teaching  in  the  acknowledgement  trans-
mitter").

4. Select a new melody if desired.
5.  Change the volume/flashlight combination if 

desired.

Attention!  Ensure  an  interference-free  wireless 
connection.  Do  not  install  the  device  in  a 
distribution box, metal housings or close to large 
metal objects.

R

Q

GB

F/B (PL)

Max. Contact load of sockets:

13 A

16 A