• The Elcometer 224 measures profile on either
flat or curved surfaces
• Available with or without memory and Bluetooth®.
• Available with either
an
integral or separate probe
.
• Separate gauge probes offer greater flexibility to suit any application
• Measurement range 0-500μm (0-20mils)
Elcometer 224
Digital Surface Profile Gauge
Model Options ( Gauges )
Part Number
Description
Integral Gauge Separate Gauge
E224C-BI
E224C-BS
Elcometer 224 Model B Digital Surface Profile Gauge
E224C-TI E224C-TS
Elcometer 224 Model T Digital Surface Profile Gauge
Range: 0-500
μm (0-20mils) Resolution: 1μm (0.1mil) Accuracy: ±5% or ±5μm (±0.2mil)
Part Number
Probe Design
T224C500US
Flat Surface: Standard
T224C500UARM
Flat Surface: Armoured
T224C500UX
Convex Surface: Standard
T224C500UXARM
Convex Surface: Armoured
Digital Surface Profile Probes / Convex Surface Profile Probes
1. Calibrate on a glass zero plate.
2. Ensure probe is 90° to substrate to ensure accurate readings.
3. Take a minimum of 10 readings over an area to establish the average surface profile.
How to measure surface profile with an elcometer 224
2
Surface Profile