MAINTENANCE
53/64
EN
6 .4 .5
Replacing the coil
The pump coil is designed and built to withstand temperatures of up to 85°C. In the event of
malfunctions or faults, replace the coil using the following procedure:
–
remove the connector (1)
–
remove the nut (2) using the key supplied
–
slide off the coil (3) and replace it
1
2
3
Fig. 52
–
refit the components, reversing the procedure above.
6 .4 .6
Replacing the capacitor
Proceed as follows to replace the capacitor:
–
detach the electrical connection from the capacitor (1)
–
remove the capacitor (2) and replace it
2
1
Fig. 53
–
refit the components, reversing the procedure above.
Summary of Contents for Firebird FB 2 K LN