95 / GB
Maintenance
NOTE:
In compliance with 811/2013 EU Regulation, the outdoor unit which is part of the system purchased carries a label related to a specifi c con-
fi guration; in case the system you chose does not match the one on the label, it is possible to retrieve the appriopriate label at www.elco.net
or by calling our Customer Centre at +44/1268546-770.
External unit data plate
Internal unit data plate
1
2
3
7
8
9
10
11
14
16
17
19
18
15
12
13
4
5
6
Legend:
1. Homologation
2. Certifi cation
3. Model
4 Performance Ratings heating circuit
5 Cooling date
6 Performance Ratings cooling circuit
7 Type of oil in the refrigerant circuit
8 Refrigerant type - load of the refrigerant
9 GWP
10 CO
2
Equivalent (t)
11 Electrical data
12 Electrical protection
13 Maximum electric power
14. Maximum pressure refrigerant circuit
15. Minimum pressure refrigerant circuit
16 Plant of manufacturing
17 Protection rating
18 Certifi cate
19 Contact address
1
2
3
4
5
9
1
0
11
M
A
X
MI
N
12
Legend:
1.
Brand
2. Manufacturer
3. Appliance model - Serial number
4. Commercial reference
5. Certifi cation number
9. Electrical data
11. Maximum heating pressure
12. Nominal power of heating
elements
Refrigerant data
MONO 04X
ODU
MONO 05X
ODU
MONO 07X
ODU
MONO 07
ODU
MONO 09
ODU
MONO 11
ODU
Refrigerant type
R410A
R410A
R410A
R410A
R410A
R410A
Load of the refrigerant
[g]
1880
1880
2770
2770
3900
3900
GWP
2088
2088
2088
2088
2088
2088
CO
2
Equivalent (t)
3,9
3,9
5,8
5,8
8,1
8,1