Troubleshooting
Compressor Test Procedures
1.
Disconnect the pressure line connection.
2.
Disconnect the Vacuum line connection.
3.
Connect the high pressure service hose on the device to the pressure line you have disconnected
from the compressor.
4.
Start the compressor from the valve test menu and stop the high pressure gauge at around 20 bar
and check that the high pressure gauge should not fall.
5.
If the high pressure gauge falls, you need to change the compresso
r
.
Service line
Power part
Vacuum line
Pressure line