background image

 

 

                                                                           

www.elcielektronik.com

                                                     19/35 

 

 

Setting

 

1-

 

DATE / TIME 

To adjust the date and time of machine. 

2-

 

DIL – LANGUAGE 
Turkish and English languages are registered in it’s own 
memory. User's request the desired language is loaded onto 
 

3-

 

SYSTEM VACUUMING 
It is a process used to vacuum the system 
 

4-

 

SERVICE( ciphered ) 
Uses to Usage reset, Tank capacity, Filter capacity and oil container setting

 

 

 

 

 

 

 

 

Summary of Contents for EKM PLUS

Page 1: ...A C Recovery Recycling and Recharge Machine Operating And Service Manual EKM plus ENGLISH...

Page 2: ...0 Recover from new tube 16 Air purge 17 Usage Information 17 Setting 18 Calibration 20 Weight calibration 20 Vacuum calibration 21 Pressure calibration 22 Inverter 23 Maintenance 15 Compressor Mainten...

Page 3: ...50Hz Display 4x20 character LCD Storage tank capacity 6 kg Scale resolution 5 gr Compressor 1 4 HP 8 cc hermetic Recovery rate 250 gr min maximum Operating range 8 C to 49 C Low pressure gauge 15 bar...

Page 4: ...Avoid contact of liquid refrigerant with the eyes and prolonged skin exposure Pressurized tank contains liquid refrigerant Never fill the refrigerant tank to more than 80 of its maximum capacity Hose...

Page 5: ...ORATOR An evaporator is a device in a process used to turn the liquid form of a chemical substance such as water into its gaseous form vapor The liquid is evaporated or vaporized into a gas form of th...

Page 6: ...6 35 Components 1 Pressure Gaugess 6 Dryer Filter 11 Compressor 2 On Off button 7 nverter optional 12 Condenser 3 Control Panel 8 Oil Seperator 13 Vacuum Pump 4 New oil bottle 9 Gas tank 14 5 Used oil...

Page 7: ...www elcielektronik com 7 35 Control Panel elcielektronik com...

Page 8: ...first use 1 Place the unit on a flat surface 2 Connect quick action coupler valves to the service hoses DO NOT OVERTIGHTEN 3 Remove aluminum foil from the vacuum pump and install oil filler cap 4 Remo...

Page 9: ...nt from the A C system 4 If you see the warning OPEN USED OIL VALVE open used oil valve SLOWLY 5 If you see the warning CLOSE USED OIL VALVE close used oil valve then press ENTER 6 Screen will display...

Page 10: ...Operations 2 Charge Refrigerant Uses to charge vehicle A C system with refrigerant 1 Connect service hoses to the vehicle and open adapters 2 Select CHARGE REFRIGERANT then press ENTER 3 There is two...

Page 11: ...clude the vacuum time Leak control amount of gas manually 1 VACUUM TIME Vacuum time entered to make the air conditioning system vacuum NOTE The purpose of this process is to remove the air water vapor...

Page 12: ...eteriorating 1 Screen will display LEAK CONTROL TIME 2 Use UP DOWN buttons to set the desired time 3 To skip leak control operation set the time to zero 4 Press ENTER to proceed WARNING Unit will stop...

Page 13: ...5 Operations 3 AMOUNT OF GAS The purpose of this process is to enter the amount of gas we want to apply to system NOTE in order to get better results we have to add gas 30 40gr hose amount to the amou...

Page 14: ...firstly required to Add New Oil 1 Screen will display ADD NEW OIL 2 Use UP DOWN buttons to select YES or NO 3 Skip oil injection by selecting NO 4 Press ENTER to proceed WARNING Open oil valve when yo...

Page 15: ...to add the amount of gas which is the hose share in this process Vehicle Database Select vehicle brand and model to charge vehicle A C system with refrigerant 1 Select VEHICLE DATABASE then press ENTE...

Page 16: ...rvice hoses to the external tank and open tank s valve 2 Open the valve of the connected service hose close the other one on manifold 3 Use UP DOWN buttons to select REC FROM VEHICLE then press ENTER...

Page 17: ...to leaks in the system The unit will perform automatic air purge when sensors detect excess air in the storage tank Operation time might differ depending on the amount of air in the tank Usage inform...

Page 18: ...www elcielektronik com 18 35 Setting Press and hold ESC button on the main menu screen for 5 seconds to enter the calibrations and settings To obtain a password call the manufacturer service...

Page 19: ...2 DIL LANGUAGE Turkish and English languages are registered in it s own memory User s request the desired language is loaded onto 3 SYSTEM VACUUMING It is a process used to vacuum the system 4 SERVIC...

Page 20: ...ct that we know the net weight A TARE to reset the weight of machine own tank weight B WEIGHT CALIBRATION when you choose this menu it is automatically measured and the object which you know the weigh...

Page 21: ...b For calibration open manifold valves and press ENTER c After a beep warning close the manifold valves and press ENTER d Machine automatically starts to countdown a timer and the number beside it als...

Page 22: ...e of machine is equalized to the atmospheric press 2 GAIN to perform this operation Combine manifold outlets with a single hose and open manifold valves Charge 100 gr Refrigerant Note the pressure of...

Page 23: ...used to provide 220 volts of energy required for operation of the device Usage Attach the power cable of the device to the socket on the back of the device Attach the RED wire of the inverter to the s...

Page 24: ...NGE COMPRESSOR OIL 1 Detach the hose from the drier filter to the compressor 2 Use new oil bottle to fill in approximately 70 gr of oil with the help of TEST menu 3 Re attach the hose 4 Go to main men...

Page 25: ...xpired filters voids warranty EKM plus filters need to be replaced every 100 kg of operation After 80 kgs of operation the unit will start reminding the user at every start up When the filter reaches...

Page 26: ...y 30 working hours or when filter drier is replaced When the color of the oil becomes dark or cloudy 1 Obtain an empty container to collect the used oil 2 Disconnect the unit from the electrical suppl...

Page 27: ...constricted Straighten hose Unit does not recover Manifold valve closed Open valve Leak in vehicle AC system Find and repair leak Service adapters closed Open adapters Scale calibration error Re cali...

Page 28: ...edied within 15 working days the manufacturer and importer must allocate another industrial product with similar functions to the use of the consumer until repair of product is completed National lega...

Page 29: ...e certificate of warranty you may refer to the General Directorate for the Protection of Consumers and Competition of the Ministry of Industry and Trade 12 Even though the consumer uses its right of r...

Page 30: ...RKING SITES 1354 STREET 1357 Qr NO 30 YEN MAHALLE ANKARA T RK YE TELEPHONE 90 312 395 53 53 PBX FAX 90 312 395 18 86 PRODUCT TYPE REFRIGERANT RECOVERY RECYCLE RECHARGE MACHINE BRAND ELC MODEL EKM PLUS...

Page 31: ...oils recommended by the manufacturer Refrigerant Tazetti Solkane AG Adge Arkema Honeywell Chemours Compressor oils PAO compressor oil Reniso PAG Reniso Triton SEZ 68 POE Reniso Triton SE 170 POE Vacu...

Page 32: ...ented management system and continuous research and development activities enable us to offer the best price to meet the expectations of the customers at highest level without compromising the quality...

Page 33: ...www elcielektronik com 33 35 Muniments SERVICE QUALITY DOCUMENT ISO 9001 2008...

Page 34: ...www elcielektronik com 34 35 Muniments BRAND RENEWAL CERTIFICATE CE DECLARATION OF CONFORMITY...

Page 35: ...www elcielektronik com 35 35 NOTE...